Dati Tecnici:

Tipo di collegamento: Pipe⇔Pipe, same diameters connection

Raccordo tubo-tubo con diam. uguale: Panel Mount Union

Raccordo tubo-tubo con diam. diverso: -

D.E. tubo applicabile (mm) D2: -

D.E. tubo applicabile (pollici) D (D1): 1/4


(i)Nota

  • Refer to the catalog for product specifications.
  • Product images may be representative images. Refer to the catalog for details.

Codice componente

Qui sono indicati i codici componente
correlati al prodotto ricercato

LQ1P2A

Panel Mount Union LQ1P Inch Size Specifications

Common Specifications

Item Model
LQ1□10 LQ1□20 LQ1□30 LQ1□40 LQ1□50 LQ1□60
Material New PFA
Maximum operating pressure (at 20°C) 1.0 MPa
Withstand pressure Refer to the withstand pressure and heat resistance performance curves.
Operating temperature 0 to 200℃

Withstand pressure and heat resistance performance

Withstand pressure and heat resistance performance curves

Withstand pressure and heat resistance performance curves

Series

Series Size Pipe connection port diameter Tube outer diameter
Inch Size
None 1/8 "1/4 "3/8 "1/2 "3/4 "1 "1/8 "3/16 "1/4 "3/8 "1/2 "3/4 "1 "
Panel Mount Union
LQ1P
1 - - - - - - - - - - - -
2 - - - - - - - - - -
3 - - - - - - - - - - -
4 - - - - - - - - - - -
5 - - - - - - - - - - -
6 - - - - - - - - - - -

Note: ○ Standard size ● With reducer

Outline/dimensions

Panel Mount Union Outline Drawing

Panel Mount Union Outline Drawing

Panel Mount Union dimensional drawing

Panel Mount Union dimensional drawing

(E): Shows the approximate dimension of the inserted tubing from the end of the nut
W: Width across flats

Panel Mount Union dimensional drawing for size 1

Panel Mount Union dimensional drawing for size 1

Panel Mount Union dimensional drawing for sizes 2 to 5

Panel Mount Union dimensional drawing for sizes 2 to 5

Panel Mount Union dimensional drawing for size 6

Panel Mount Union dimensional drawing for size 6

Model Applicable tube outer diameter E H J K L1L2M t W1W2
LQ1P1A 1/8 "10 - 6 10.5 17 44 11.5 8 11 13
LQ1P2A□□ 1/4 "15 14 6 14.5 23.5 55.5 16.5 8 15 17
LQ1P2B□□ 3/16 "
LQ1P3A□□ 3/8 "20 17 7 20.5 30 69 23 8 21 24
LQ1P3B□□ 1/4 "
LQ1P4A□□ 1/2 "24 21 7 24.5 35 78.5 28 8 26 28
LQ1P4B□□ 3/8 "
LQ1P5A□□ 3/4 "29 26 9 36.5 43.5 100 39 9 39 43
LQ1P5B□□ 1/2 "
LQ1P6A□□ 1 "39.5 36 10 48.5 58.5 133 49 10 51 55
LQ1P6B□□ 3/4 "

Units: mm

Notes For Tubing

1. Use the dedicated tool for connecting tubes.
Refer to "High-Purity Fluoropolymer Fittings / Hyper Fitting LQ1, 2 Series Work Procedure Instructions" for notes regarding tube connections and dedicated tools.

Dedicated Tool Outline Drawing

Dedicated Tool Outline Drawing

2. Tighten the nut as far as the end surface of the main body. In order to confirm that it has properly reached the end surface of the main body, tighten by a further 1/8th (approx.) of a turn. You will know that you have sufficiently tightened the nut if it will turn no further past this point. Be sure to also refer to the appropriate tightening torques shown below.

Body size Torque (N·m)
2 0.3 to 0.4
3 0.8 to 1.0
4 1.0 to 1.2
5 2.5 to 3.0
6 5.5 to 6.0

Note: For body size 1, tighten by hand.

Codice componente
LQ1P2A
Codice componente
Prezzo unitario standard
Quantità minima d'ordineSconto volumi elevati
Giorni
spedizione standard
?
Tipo di collegamento Raccordo tubo-tubo con diam. uguale Raccordo tubo-tubo con diam. diverso D.E. tubo applicabile (mm) D2 D.E. tubo applicabile (pollici) D (D1) D.E. tubo applicabile (pollici) D2 Size of Body

30.45 €

1 4 giorni Pipe⇔Pipe, same diameters connectionPanel Mount Union--1/4-2

Loading...

  1. 1

Informazioni di base

Tipo Fitting Body Materiale corpo principale PFA Max. temperatura d'esercizio(°C) 200
Packaging Confezionamento sterile classe M3.5 Equivalente

Si trova sulla pagina di Raccordi in fluoroplastica / Raccordi per guaine in fluoropolimero, serie LQ1, Raccordo per montaggio a pannello, dimensioni in pollici, il codice articolo è il seguente: LQ1P2A.
Ulteriori dettagli concernenti specifiche e dimensioni si trovano sotto il codice prodotto LQ1P2A.

Tipologia prodotto

Codice componente
LQ1P1A
LQ1P2A22
LQ1P2A2C
LQ1P2B
LQ1P3A
LQ1P3A3B
Codice componentePrezzo unitario standardQuantità minima d'ordineSconto volumi elevatiGiorni
spedizione standard
?
Tipo di collegamento Raccordo tubo-tubo con diam. uguale Raccordo tubo-tubo con diam. diverso D.E. tubo applicabile (mm) D2 D.E. tubo applicabile (pollici) D (D1) D.E. tubo applicabile (pollici) D2 Size of Body

21.73 €

1 Preventivo Pipe⇔Pipe, same diameters connectionPanel Mount Union--1/8-1

30.45 €

1 26 giorni Pipe⇔Pipe, different diameters connection-[Giunto riduttore] Giunto passaparete, riduttore41/4-2

30.45 €

1 26 giorni Pipe⇔Pipe, different diameters connection-[Giunto riduttore] Giunto passaparete, riduttore-1/41/82

30.45 €

1 26 giorni Pipe⇔Pipe, same diameters connectionPanel Mount Union----2

41.31 €

1 4 giorni Pipe⇔Pipe, same diameters connectionPanel Mount Union--3/8-3

41.35 €

1 26 giorni Pipe⇔Pipe, different diameters connection-[Giunto riduttore] Giunto passaparete, riduttore-3/81/43

Supporto tecnico