Drain Separator For Vacuums AMJ Series product image
Usable fluids | Air |
---|---|
Operating pressure | -100 kPa to 1.0 MPa |
Proof pressure | 1.5 MPa |
Ambient and fluid temperature | 5 to 60°C |
Water drop removal ratio | 90% |
Element replacement period | 2 years or when pressure drops to 0.02 MPa |
Model | AMJ3000 | AMJ4000 | AMJ5000 |
---|---|---|---|
Recommended Flow Rate L/min (ANR) | 200 | 300 | 500 |
Port Size | 1/4 and 3/8 | 3/8, 1/2 | 3/4, 1 |
Weight (kg) | 0.3 | 0.6 | 1.1 |
Compatible models | AMJ3000 | AMJ4000 | AMJ5000 |
---|---|---|---|
Bracket assembly (with 2 mounting screws) | AF30P-050AS | AF40P-050AS | AF50P-050AS |
Representative model number
Representative model number (case assembly)
Drain Separator For Vacuums AMJ Series structural diagram
Number | Part Name | Material | Note |
---|---|---|---|
1 | Body | Aluminum alloy | Platinum silver coated |
Number | Part Name | Material | Part Number | ||
---|---|---|---|---|---|
AMJ3000 | AMJ4000 | AMJ5000 | |||
2 | Element assembly | - | AMJ-EL3000 | AMJ-EL4000 | AMJ-EL5000 |
3 | Case assembly* | - | AMJ-CA30-□ | AMJ-CA40-□ | AMJ-CA40-□ |
4 | O-ring | NBR | C3SFP-260S | C4SFP-260S | C4SFP-260S |
5 | O-ring | NBR | - | - | 111,710 |
6 | Spacer | NBR | AMJ-SA001 | AMJ-SA002 | AMJ-SA003 |
(Unit: mm)
AMJ3000/AMJ4000 dimensional drawing
(Unit: mm)
AMJ5000 dimensional drawing
Model | Port Size Q | A | B* | C | D | Bracket mounting dimensions | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
E | F | G | H | J | K | L | M | ||||||
AMJ3000 | 1/4 and 3/8 | 53 | 165 (166) | 14 | 53 | 16 | 41 | 40 | 23 | 6.5 | 8 | 53 | 2.3 |
AMJ4000 | 3/8, 1/2 | 70 | 199 (202) | 18 | 70 | 17 | 50 | 54 | 26 | 8.5 | 10.5 | 70 | 2.3 |
AMJ5000 | 3/4, 1 | 90 | 278 (280) | 24 | 90 | 23 | 70 | 66 | 35 | 11 | 13 | 90 | 3.2 |
AMJ Series drain separators for vacuums that are capable of single-action element replacement.
[Features]
· Removes water droplets from air by simply installing in vacuum lines.
· Prevents malfunction of vacuum pumps and ejectors.
· Over 90% of water droplets can be removed using a dedicated element.
· The provision of a drain cock makes it possible to discharge the drain manually after breaking the vacuum.
· Even when the element is saturated with water, there is almost no drop in pressure (increase in resistance).