Fluoropolymer Tubing TL/TIL Series Specifications

Fluoropolymer Tubing TL/TIL Series: related images

Appearance of Fluoropolymer Tubing TL/TIL Series

Fluoropolymer Tubing TL/TIL Series: related images

Burst Pressure Drop Curve

Series List And Specifications

-Metric Sizes (TL series)Inch Sizes (TIL series)
Tubing modelTL0403TL0604TL0806TL1008TL1210TL1916TIL01TIL05TIL07TIL11TIL13TIL19TIL25
Nominal diameter------1/8 "3/16 "1/4 "3/8 "1/2 "3/4 "1 "
Tubing Sizeø4 × ø3ø6 × ø4ø8 × ø6ø10 × ø8ø12 × ø10ø19 × ø161/8 "× 0.086 "3/16 "× 1/8 "1/4 "×5/32 "3/8 "×1/4 "1/2 "×3/8 "3/4 "×5/8 "1 "×7/8 "
Outer diameter (mm)Basic diameter4681012193.184.756.359.5312.719.0525.4
Tolerance±0.1+0.2
-0.1
±0.1+0.2
-0.1
Thickness mmBasic diameter0.511.50.50.81.21.6
Tolerance±0.05±0.1±0.15±0.05±0.08±0.12±0.15
Bundle10 m--------
20 m
50 m
100 m-
16 m (50 ft)------
33 m (100 ft)------
Straight pipe2 m
ColorTranslucent (material color)
Applicable fluidsSee catalog
Applicable fittingsFluoropolymer fittings LQ Series
Maximum operating pressure
MPa
20°C1.01.01.00.90.70.61.01.01.01.01.00.70.5
100°C0.450.640.430.330.270.240.590.620.730.620.430.260.19
200°C0.210.290.200.150.120.110.270.280.340.280.200.120.09
260°C0.090.120.080.060.050.050.110.120.140.120.080.050.04
Burst pressure MPa (at 20°C)4.96.94.73.62.92.66.46.77.96.74.62.82.0
Minimum bending radius
mm
Recommended radius3535601001302202025356095220400
Tube close bend radius202040651101601220203060160290
Maximum operating temperature (fixed usage)260°C
MaterialSuper PFA

Note 1) When using the product at a temperature other than those shown in the table above, use it at the maximum operating pressure or less that is calculated from the following formula.
(Maximum operating pressure) = 1/4 × (Burst pressure drop coefficient) × (Burst pressure at 20°C)
Note 2) When using a fluid in liquid form, the surge pressure must be no more than the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to the fittings and tubing. Furthermore, abnormal temperature rise caused by adiabatic compression may result in the tubing bursting.
Note 3) Do not use this product in a manner in which the tubing is not fixed. Observe the lesser value of the maximum operating pressure between the tubing and fittings. A material change over a long duration or due to high temperature may cause leakage. Perform periodic maintenance and replace with a new product immediately when abnormalities are detected. (Refer to the notes on maintenance in the catalog.) For other precautions, refer to "Fittings & Tubing Precautions" in the catalog. When using the fluoropolymer fittings, refer to the precautions in the catalog.
Note 4) The minimum bending radius is the value measured as shown in the figure on the left.

  • Use a tube above the recommended minimum bending radius.
  • The tubing may be bent if used under the recommended minimum bending radius. Therefore, refer to the tube close bend radius and make sure that the tubing is not bent or flattened.
  • The tube close bend radius is not guaranteed. The value of 2R is the value measured with a flattened tube using the method shown in the figure on the left.
  • The minimum bending radius shown above does not apply to straight pipes (2 m).

Note 5) As for other commercial items, there are some cases in which the item cannot be connected due to the tolerance of dimensions.

Fluoropolymer Tubing TL/TIL Series: related images

How to measure the minimum bending radius

Bend the tubing into a U shape at a temperature of 20°C. Fix one end and close the loop gradually. Measure 2R when the deformed ratio of the tubing diameter at bending reaches 5%.

Eluting fluorine ion amount Note 6)
A 15‑g piece of fluororesin tubing is cut off, washed in DI water (pure water) and immersed in 15 mL of 25% methyl alcohol extract at room temperature for 24 hours. Then the extract is diluted with DI water (pure water) and subjected to a quantitative analysis of fluorine ions.

  • Fluoride ion: 0.1 mg/g or less

Eluting metal ion amount Note 6)
The interior of the fluororesin tubing is washed with super deionized water. Approximately 20 g of super-high-purity hydrofluoric acid (48%) is measured and injected into the tubing. The interior wall of the tubing is immersed at normal temperature for one week with both ends of the tubing plugged. Then the extract is diluted with super deionized water and subjected to a quantitative analysis on Al, Fe, Ni, Na and Ca by the stripping method.

  • Al: 4.5 ng/cm2
  • Fe: 0.3 ng/cm2
  • Ni: 0.2 ng/cm2
  • Na: 7.1 ng/cm2
  • Ca: 1.3 ng/cm2

Note 6) Figures shown in tables are representative values, not guaranteed values.

Elenco numeri di parte

Numero di articoli

D.E. D

(Ø)

D.E. [Distinzione]

Bundle winding length

(m)

Applicable Tube Size

Pressione d'esercizio massima

(MPa)

Lunghezza rettilinea

(m)

Quantità minima d'ordine
3.18
Fino a 4
-
Misura in pollici
1
2
1 pezzi
3.18
Fino a 4
50
Misura in pollici
1
-
1 pezzi
-
Fino a 5
-
Misura in pollici
1
2
1 pezzi
-
Fino a 5
20
Misura in pollici
1
-
1 pezzi
-
Fino a 5
50
Misura in pollici
1
-
1 pezzi
6.35
Fino a 7
-
Misura in pollici
1
2
1 pezzi
9.53
Fino a 10
-
Misura in pollici
1
2
1 pezzi
-
Fino a 20
-
Misura in pollici
0.7
2
1 pezzi
-
Fino a 30
20
Misura in pollici
0.5
-
1 pezzi
-
Fino a 30
50
Misura in pollici
0.5
-
1 pezzi
10
Fino a 10
20
Misura metrica
0.9
-
1 pezzi
Prezzo unitario (IVA esclusa)(Prezzo unitario IVA inclusa)
Giorni spedizione standard
12.10 €
( 14.40 € )
26 giorni lavorativi
169.60 €
( 201.82 € )
4 giorni lavorativi
29.35 €
( 34.93 € )
4 giorni lavorativi
166.37 €
( 197.98 € )
39 giorni lavorativi
415.89 €
( 494.91 € )
4 giorni lavorativi
55.82 €
( 66.43 € )
26 giorni lavorativi
119.06 €
( 141.68 € )
39 giorni lavorativi
255.58 €
( 304.14 € )
4 giorni lavorativi
1,991.35 €
( 2,369.71 € )
39 giorni lavorativi
4,978.26 €
( 5,924.13 € )
4 giorni lavorativi
462.44 €
( 550.30 € )
26 giorni lavorativi

Ulteriori informazioni

Informazioni di base

Fluoropolymer tubing with a highly smooth internal surface.
[Features]
· Maximum operating pressure 1.0 MPa or less (at 20°C).
· Maximum operating temperature: 260°C (varies depending on the conditions).
[Applications]
· Suitable for applications requiring a small amount of elution of fluorine ions.

Attenzione

  • I valori massimi di pressione operativa elencati sono a 20°C. Consulta il catalogo per i dettagli.
  • Le ultime cifre dei codici prodotto indicano la lunghezza dei tubi.