Tubazione in fluoropolimero morbido serie TD/TID

Tubazione in fluoropolimero morbido serie TD/TID
Compatible with Japan's Food Sanitation Law.
[Features]
· Flexibility: Improved by approx. 20%.
· Operating temperature: Max. 260°C.
[Applications]
· Suitable for applications which require flexibility.

(i)Nota

  • I valori massimi di pressione operativa elencati sono pari a 20°C o meno. Consulta il catalogo per i dettagli.
  • Le ultime cifre dei codici prodotto indicano la lunghezza dei tubi.

Codice componente

Qui sono indicati i codici componente
correlati al prodotto ricercato

Specifications of Soft Fluoropolymer Tubing TD Series

SizeMetric Size
NominalTD0425TD0604TD0806TD1075TD1209
Outer diameter (mm)4681012
Inner diameter (mm)2.5467.59
Roll10 m
20 m
ColorTranslucent (material color)
Applicable FluidsSee the catalog for applicable fluids.
FluidNote 1)Air, waterNote 1), inert gas
Applicable fittingsNote 1)Insert fittings KF Series
Stainless steel 316 insert fittings KFG2 Series
Miniature fittings M, MS Series (Hose-nipple type)
Fluoropolymer fittings LQ Series
Maximum operating pressure (MPa)20°C1.61.40.90.90.9
100°C0.90.70.50.50.5
200°C0.450.350.250.250.25
260°C0.230.20.150.150.15
Minimum bending radius mmNote 3)Recommended radius1525455575
Tube close bend radius816313541
Maximum operating temperature (fixed usage)260°C
MaterialModified PTFE (Polytetrafluoroethylene resin)

Note 1) When using a liquid fluid, the surge pressure must be under the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to the fittings and tubing. Furthermore, abnormal temperature rise caused by adiabatic compression may result in the tubing bursting.
Note 2) Do not use this product in a manner in which the tubing is not fixed. Observe the lesser value of the maximum operating pressure between the tubing and fittings. A material change over a long duration or due to high temperature may cause leakage. Perform periodic maintenance and replace with a new product immediately when abnormalities are detected.
Note 3) The minimum bending radius is the representative value measured as shown in the figure on the left.

  • Use a tube above the recommended minimum bending radius.
  • The tubing may be bent if used under the recommended minimum bending radius. Therefore, refer to the tube close bend radius and make sure that the tubing is not bent or flattened.
  • The tube close bend radius is not guaranteed. The value of 2R is measured with a bent or flattened tube.
Fluoropolymer Tubing TD/TID Series: related images

How to measure the minimum bending radius

Bend the tubing into a U shape at a temperature of 20°C. Fix one end and close the loop gradually. Measure 2R when the deformed ratio of the tubing diameter at bending reaches 5%.

Fluoropolymer Tubing TD/TID Series: related images

Maximum operating pressure

Specifications of Soft Fluoropolymer Tubing TID Series

SizeInch Size
NominalTID01TID05TID07TID11TID13
Outer diameterinch1/8 "3/16 "1/4 "3/8 "1/2 "
mm3.184.756.359.5312.7
Inner diameterinch0.086 "0.124 "
(1/8 ")
0.156 "
(5/32 ")
0.25 "
(1/4 ")
0.374 "
(3/8 ")
mm2.183.153.956.339.5
Roll8 m (25 ft)
16 m (50 ft)
ColorTranslucent (material color)
Applicable FluidsSee the catalog for applicable fluids.
FluidNote 1) Air, waterNote 1), inert gas
Applicable fittingsNote 2) Stainless steel 316 inert fittings KFG2 series
Fluoropolymer Fittings LQ Series
Maximum operating pressure (MPa)20°C1.41.41.61.40.9
100°C0.70.70.90.70.5
200°C0.350.350.450.350.25
260°C0.20.20.230.20.15
Minimum bending radius mmNote 3) Recommended radius1520254075
Tube close bend radius910152342
Maximum operating temperature (fixed usage)260°C
MaterialModified PTFE (Polytetrafluoroethylene resin)

Note 1) When using a liquid fluid, the surge pressure must be under the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to the fittings and tubing. Furthermore, abnormal temperature rise caused by adiabatic compression may result in the tubing bursting.
Note 2) Do not use this product in a manner in which the tubing is not fixed. Observe the lesser value of the maximum operating pressure between the tubing and fittings. A material change over a long duration or due to high temperature may cause leakage. Perform periodic maintenance and replace with a new product immediately when abnormalities are detected.
Note 3) The minimum bending radius is the representative value measured as shown in the figure on the left.

  • Use a tube above the recommended minimum bending radius.
  • The tubing may be bent if used under the recommended minimum bending radius. Therefore, refer to the tube close bend radius and make sure that the tubing is not bent or flattened.
  • The tube close bend radius is not guaranteed. The value of 2R is measured with a bent or flattened tube.
Fluoropolymer Tubing TD/TID Series: related images

How to measure the minimum bending radius

Bend the tubing into a U shape at a temperature of 20°C. Fix one end and close the loop gradually. Measure 2R when the deformed ratio of the tubing diameter at bending reaches 5%.

Fluoropolymer Tubing TD/TID Series: related images

Maximum operating pressure

Codice componente
TD0425-10
TD0425-20
TD0604-10
TD0604-20
TD0806-10
TD0806-20
TD1075-10
TD1075-20
TD1209-10
TD1209-20
TID01-8
TID01-16
TID05-8
TID05-16
TID07-8
TID07-16
TID11-8
TID11-16
TID13-8
TID13-16
Codice componente
Prezzo unitario standard
Quantità minima d'ordineSconto volumi elevati
Giorni
spedizione standard
?
D.E. D
(Ø)
D.E. [Distinzione] D.I. d
(Ø)
D.I. [Distinzione] Min. raggio di curvatura
(mm)
Bundle winding length
(m)
Applicable Tube Size Pressione d'esercizio massima
(MPa)

63.35 €

1 4 giorni 4Fino a 42.5Fino a 31510Misura metrica1.6

126.66 €

1 4 giorni 4Fino a 42.5Fino a 31520Misura metrica1.6

127.45 €

1 4 giorni 6Fino a 64Fino a 42510Misura metrica1.4

254.89 €

1 66 giorni 6Fino a 64Fino a 42520Misura metrica1.4

186.23 €

1 22 giorni 8Fino a 86Fino a 64510Misura metrica0.9

372.39 €

1 4 giorni 8Fino a 86Fino a 64520Misura metrica0.9

293.69 €

1 22 giorni 10Fino a 107.5Fino a 85510Misura metrica0.9

587.40 €

1 4 giorni 10Fino a 107.5Fino a 85520Misura metrica0.9

418.98 €

1 4 giorni 12Fino a 159Fino a 9-10Misura metrica0.9

837.94 €

1 4 giorni 12Fino a 159Fino a 9-20Misura metrica0.9

35.58 €

1 4 giorni 3.18Fino a 4-Fino a 3158Misura in pollici1.4

71.16 €

1 4 giorni 3.18Fino a 4-Fino a 31516Misura in pollici1.4

66.81 €

1 4 giorni -Fino a 5-Fino a 4208Misura in pollici1.4

133.68 €

1 26 giorni -Fino a 5-Fino a 42016Misura in pollici1.4

131.53 €

1 4 giorni 6.35Fino a 7-Fino a 4258Misura in pollici1.6

262.98 €

1 4 giorni 6.35Fino a 7-Fino a 42516Misura in pollici1.6

275.94 €

1 4 giorni 9.53Fino a 10-Fino a 7408Misura in pollici1.4

551.81 €

1 4 giorni 9.53Fino a 10-Fino a 74016Misura in pollici1.4

385.85 €

1 4 giorni -Fino a 15-Fino a 10-8Misura in pollici0.9

771.69 €

1 22 giorni -Fino a 15-Fino a 10-16Misura in pollici0.9

Loading...

  1. 1

Informazioni di base

Tipo Dritto Uso servizio taglio NA Materiale Fluororesina
Liquido applicabile Acqua / Aria Ambiente d'esercizio Standard / Resistenza chimica Colore Trasparente
Temperatura d'esercizio(°C) fino a 260

Supporto tecnico