• Lavori di manutenzione: questa pagina non sarà disponibile dalle ore 3:00 21/4/2024 alle ore 0:00 (CET) 22/4/2024 per lavori di manutenzione al server. Ci scusiamo per questo inconveniente.

EX120 / 121 / 122, Sistema in Bus di campo

EX120 / 121 / 122, Sistema in Bus di campo
Fieldbus System (For Output) EX120/121/122 Series compatible with a variety of communication networks.
[Features]
· Output type for solenoid valve.

(i)Nota

  • Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.
  • Refer to the manufacturer's catalog for specification and material details.
  • Product images may be representative images. Refer to the catalog for details.

Codice componente

Qui sono indicati i codici componente
correlati al prodotto ricercato

Fieldbus System (For Output), EX120/121/122 Series Specifications

SI Unit Model Number Notation

SI Unit model number notation image

SI Unit model number notation image

  • *1: DN1 occupied points are 16 inputs and 16 outputs. DN1-X26 occupied points are 0 inputs and 16 outputs.
  • *2: A manifold part number is not specified for this model.
    Please inquire regarding the manifold integrated type.

Specifications

Communication Specifications Terminating Resistor Not provided
Internal Current Consumption (Unit) 100 mA or less
Environment Resistance Enclosure IP20
Operating Temperature Range 0 to +55°C (valve 8 points ON)
0 to +50℃ (valve 16 points ON)
Operating Humidity Range 35 to 85% RH (No condensation)
Withstand Voltage 1,500 V AC for 1 minute between external terminal and housing
Insulation Resistance 500 V DC, 2 MΩ or more between external terminal and housing
Model EX12□-SDN1 EX12□-SDN1-X26 EX12□-SMJ1 EX12□-SCS1
EX12□-SCS2
Communication Specifications Protocol Name DeviceNetTM CC-Link Made by OMRON
CompoBus/S
Version*1 Release 2.0 Ver. 1.10 -
Communication Speed 125/250/500 kbps 156/625 kbps
2.5 M / 5 M / 10 Mbps
750 kbps
Configuration File*2 EDS file CSP + file -
I/O Occupation Area (No. of Inputs/No. of Outputs) 16/16 0/16 32/32
(1 station, remote I/O stations)
SCS1: 0/16
SCS2: 0/8
Power Supply Voltage For Control 11 V DC to 25 V DC 15 to 30 V DC 14 V DC to 26.4 V DC
For Valve 24 V DC +10%/-5%
Output Specifications Output Format Sink/NPN (positive common)
Number of Outputs 16 points SCS1: 16 points
SCS2: 8 points
Connection Load SMC solenoid valve 24 V DC, 2.1 W or less with surge voltage suppressor circuit
Output if Communication Error Clear Hold/Clear
(Switch setting)
Clear Hold/Clear
(Switch setting)
Standards CE marking
Weight EX120: 110 g or less, EX121: 140 g or less, EX122: 130 g or less
Accessories Communication connector 1 pc., power supply connector 1 pc. -
  • *1: Please note that the version is subject to change.
  • *2: Configuration files can be downloaded from the manufacturer's webpage.
Model EX12□-SUH1 EX12□-SCM1 EX12□-SCM3
Communication Specifications Protocol Name Made by NKE
Fieldbus H System
CompoNet
Communication Speed 29.4 kbps 93.75 kbps/1.5 Mbps/3 Mbps/4 Mbps
Configuration File - EDS file*1
I/O Occupation Area (No. of Inputs/No. of Outputs) 0/16
Power Supply Voltage For Control 24 V DC ±10%
(Common power supply)
14 V DC to 26.4 V DC
For Valve 24 V DC +10%/-5%
Output Specifications Output Format Sink/NPN (positive common) Sink/NPN (positive common) Source/PNP (Negative common)
Number of Outputs 16 points
Connection Load SMC solenoid valve 24 V DC, 2.1 W or less with surge voltage suppressor circuit
Output if Communication Error Clear Hold/Clear (setting via network)
Standards - CE marking
Weight EX120: 110 g or less
EX121: 140 g or less
EX122: 130 g or less
EX120: 100 g or less
EX121: 120 g or less
EX122: 110 g or less (including accessories)
Accessories - Power supply connector (EX9-CP2) 1 pc.*2
  • *1: Configuration files can be downloaded from the manufacturer's webpage.
  • *2: Communication connector (for the opposite side) is not provided.

Fieldbus System (For Output), EX120/121/122 Series Dimensions

EX120

 

(Unit: mm)

 

EX120-SDN1(-X26) dimensional drawing

EX120-SDN1(-X26) dimensional drawing

 

(Unit: mm)

 

EX120-SMJ1, SCS□, SUH1 dimensional drawing

EX120-SMJ1, SCS□, SUH1 dimensional drawing

 

(Unit: mm)

 

EX120-SCM□ dimensional drawing

EX120-SCM□ dimensional drawing

EX121

 

(Unit: mm)

 

EX121-SDN1(-X26) dimensional drawing

EX121-SDN1(-X26) dimensional drawing

 

(Unit: mm)

 

EX121-SMJ1, SCS□, SUH1 dimensional drawing

EX121-SMJ1, SCS□, SUH1 dimensional drawing

 

(Unit: mm)

 

EX121-SCM□ dimensional drawing

EX121-SCM□ dimensional drawing

EX122

 

(Unit: mm)

 

EX122-SDN1(-X26) dimensional drawing

EX122-SDN1(-X26) dimensional drawing

 

(Unit: mm)

 

EX122-SMJ1, SCS□, SUH1 dimensional drawing

EX122-SMJ1, SCS□, SUH1 dimensional drawing

 

(Unit: mm)

 

EX122-SCM□ dimensional drawing

EX122-SCM□ dimensional drawing

Codice componente
EX120-SCM1
EX120-SCM3
EX120-SCS1
EX120-SDN1
EX120-SMJ1
EX120-SSL1
EX121-SCM3
EX121-SCS1
EX121-SDN1
EX121-SMJ1
EX121-SSL1
EX122-SCM3
EX122-SCS2
EX122-SDN1
EX122-SMJ1
Codice componente
Prezzo unitario standard
Quantità minima d'ordineSconto volumi elevati
Giorni
spedizione standard
?
Interfaccia valvola Protocollo di comunicazione Formato uscita

230.77 €

1 26 giorni A innestoCompoNet NPNSink/NPN (comune positivo)

230.77 €

1 4 giorni A innestoCompoNet PNPOrigine/PNP (comune negativo)

207.73 €

1 26 giorni A innestoOMRON CompoBus/S (16 uscite)Sink/NPN (comune positivo)

450.74 €

1 4 giorni A innestoDeviceNet (16 ingressi/16 uscite)Sink/NPN (comune positivo)

207.52 €

1 4 giorni A innestoCC-LinkSink/NPN (comune positivo)

207.68 €

1 26 giorni A innestoDispositivo Panasonic SUNX S-LINK (16 uscite)Sink/NPN (comune positivo)

260.21 €

1 26 giorni Cavo piatto montaggio su guida DINCompoNet PNPOrigine/PNP (comune negativo)

234.13 €

1 4 giorni Cavo piatto montaggio su guida DINOMRON CompoBus/S (16 uscite)Sink/NPN (comune positivo)

441.81 €

1 4 giorni Cavo piatto montaggio su guida DINDeviceNet (16 ingressi/16 uscite)Sink/NPN (comune positivo)

325.37 €

1 Preventivo Cavo piatto montaggio su guida DINCC-LinkSink/NPN (comune positivo)

234.03 €

1 26 giorni Cavo piatto montaggio su guida DINDispositivo Panasonic SUNX S-LINK (16 uscite)Sink/NPN (comune positivo)

230.77 €

1 26 giorni A innesto montaggio su guida DINCompoNet PNPOrigine/PNP (comune negativo)

183.08 €

1 26 giorni A innesto montaggio su guida DINOMRON CompoBus/S (8 uscite)Sink/NPN (comune positivo)

460.29 €

1 4 giorni A innesto montaggio su guida DINDeviceNet (16 ingressi/16 uscite)Sink/NPN (comune positivo)

304.63 €

1 4 giorni A innesto montaggio su guida DINCC-LinkSink/NPN (comune positivo)

Loading...

  1. 1

Informazioni di base

Tipo Solenoide

Supporto tecnico