ASR*30 / ASQ*30, valvola di risparmio aria (valvola PFC / QFC) , sistema metrico (ASR630F-04-12S)

ASR*30 / ASQ*30, valvola di risparmio aria (valvola PFC / QFC) , sistema metrico ASR630F-04-12S
  • In Offerta fino al 30/11/2024

Dettagli del prodotto:

Codice articolo del costruttore: ASR630F-04-12S

Marca: SMC

Prezzo: 54.37

Tempi di consegna: Stesso giorno


Dati Tecnici:

Opzione controdado: blocco a forma dado

Temperature ambiente e fluido: -5~60 °C

Connection Dia.: 1/2

Option: Pressione regolata variabile (0.1–0.3MPa)

Applicable Tube O.D. mm: 12 mm


(i)Nota

  • ■ SMC Air Cylinder Product Selection and Technical Information
    The featured products page can be found here.

    ■ SMC Product Line
    Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.
    Click here for a quotation or to make an order if you have a model number.

    ■ Products Planned for Online Release
    Air cylinder-related product pages will be released on this site on an ad-hoc basis.
    *Vacuum equipment, FRLs, solenoid valves, etc., will also be released on dedicated pages on this site on an ad-hoc basis.
    *The information above is correct as of December 2018.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

Codice componente

Qui sono indicati i codici componente
correlati al prodotto ricercato

ASR630F-04-12S

Air-Saving Valve: Pressure Valve / Flow Valve ASR Series / ASQ Series Specifications

ASR Series (Pressure Valve) external appearance

ASR Series (Pressure Valve) external appearance

ASR Series (Pressure Valve) connection diagram

ASR Series (Pressure Valve) connection diagram

Regulator with check valve and flow control valve integrated into a single construction.

ASQ Series (Flow Valve) external appearance

ASQ Series (Flow Valve) external appearance

ASQ Series (Flow Valve) structure drawing

ASQ Series (Flow Valve) structure drawing

Pilot valve and two-way flow control valve integrated into a single construction.

Model

Model Port Size Applicable Tubing Outer Diameter (mm)
Pressure Valve Flow Valve 6 8 10 12
ASR430F-02 ASQ430F-02 R 1/4 -
ASR530F-02 ASQ530F-02 R 1/4
ASR530F-03 ASQ530F-03 R 3/8
ASR630F-03 ASQ630F-03 R 3/8 - -
ASR630F-04 ASQ630F-04 R 1/2 - -

Flow Rate Characteristics (Pressure Valve / ASR Series [Inlet Pressure 0.5 MPa])

ASR430F flow rate characteristics

ASR430F flow rate characteristics

ASR530F flow rate characteristics

ASR530F flow rate characteristics

*The flow rate characteristics are representative values.

ASR Series (Pressure Valve) Drawing

 

(Units: mm)

 

Variable set pressure type dimensional drawing 1

Variable set pressure type dimensional drawing 1

Variable set pressure type dimensional drawing 2

Variable set pressure type dimensional drawing 2

Fixed set pressure type (-F20) dimensional drawing 1

Fixed set pressure type (-F20) dimensional drawing 1

Fixed set pressure type (-F20) dimensional drawing 2

Fixed set pressure type (-F20) dimensional drawing 2

Model d*1 T H D1 D2 D3 L1 L2 L3*2
ASR430F-02-06S, -F20 6 R 1/4 17 18.5 20 21.5 57.7 34.9 63.7
ASR430F-02-08S,-F20 8 58.7 35.9
ASR430F-02-10S,-F20 10 53.8 31
ASR530F-02-06S,-F20 6 R 1/4 21 18.5 24.3 25.3 62.9 36.5 67.3
ASR530F-02-08S,-F20 8 63.9 37.5
ASR530F-02-10S,-F20 10 59 32.6
ASR530F-02-12S,-F20 12 20.9 60.8 34.4
ASR530F-03-06S,-F20 6 R 3/8 21 18.5 24.3 25.3 62.9 36.5 67.3
ASR530F-03-08S,-F20 8 63.9 37.5
ASR530F-03-10S,-F20 10 59 32.6
ASR530F-03-12S,-F20 12 20.9 60.8 34.4
ASR630F-03-10S,-F20 10 R 3/8 25 18.5 29.7 30 62.8 32.6 86.3
ASR630F-03-12S,-F20 12 20.9 64.6 34.4
ASR630F-04-10S,-F20 10 R 1/2 25 18.5 29.7 30 62.8 32.6 86.3
ASR630F-04-12S,-F20 12 20.9 64.6 34.4
Model L4*3 L5*4 L6 A1*5 A2*5 M Weight (g)*6
Max. MIN. Max. MIN. *1 *2
ASR430F-02-06S, -F20 45.6 50.6 45.6 23 44.6 39.6 16.8 17 111 89
ASR430F-02-08S,-F20 18.5 114 93
ASR430F-02-10S,-F20 21 105 82
ASR530F-02-06S,-F20 49.2 55.8 50.8 25.9 49.8 44.8 18.8 17 150 127
ASR530F-02-08S,-F20 18.5 153 130
ASR530F-02-10S,-F20 21 143 120
ASR530F-02-12S,-F20 22 146 122
ASR530F-03-06S,-F20 49.2 57.4 52.4 25.9 51 46 20 17 160 137
ASR530F-03-08S,-F20 18.5 163 140
ASR530F-03-10S,-F20 21 153 130
ASR530F-03-12S,-F20 22 156 133
ASR630F-03-10S,-F20 65.5 67.6 60.1 27.7 61.2 53.7 20.6 21 237 219
ASR630F-03-12S,-F20 22 239 221
ASR630F-04-10S,-F20 65.5 71.1 63.6 27.7 62.9 55.4 24.1 21 257 239
ASR630F-04-12S,-F20 22 259 239

*1: d indicates the applicable tubing outer diameter.
*2: L3 is the dimension for the variable set pressure type.
*3: L4 is the dimension for the fixed set pressure type.
*4: Reference dimensions.
*5: A1 and A2 are reference dimensions after installation.
*6: *1 is the weight for the variable set pressure type and *2 is the weight for the fixed set pressure type.

Precautions

Selection

  • *Keep the set pressure range of the outlet pressure of the pressure valve within 85% of the inlet pressure.
  • *If the value exceeds 85%, the pressure may become unstable, affected by the fluctuation of the inlet pressure.

Installation

  • *Check the rotational speed of the needle valve and the pressure adjusting screws. Since it has a pull-out stop mechanism, it will not rotate past the limit. Confirm the rotational speed for the product being used, as excessive turning of the needle and the pressure adjusting screws will cause damage.
  • *The valve cannot be used if there are fluctuations of the load. The actuator may jerk during operation.
  • *In case a closed-center solenoid valve is used, switch to the center position only after pressure charge inside the cylinder at the stroke end is completed. If the pressure charge is insufficient, the cylinder may jerk after restart.
  • *When the product is used for an actuator operating vertically, the actuator may lurch depending on the load. Refer to the manufacturer's catalog regarding the adjustment method.

Other

  • *See the manufacturer's catalog for information other than the above.
Codice componente
ASR630F-04-12S
Codice componente
Prezzo unitario standard
Quantità minima d'ordineSconto volumi elevati
Giorni
spedizione standard
?
Opzione controdado Temperature ambiente e fluido
(°C)
Connection Dia. Option Applicable Tube O.D. mm
(mm)
Body Size Classificazione del prodotto

54.37 €

38.06 €

1 Stesso giorno

Stock

blocco a forma dado-5~601/2Pressione regolata variabile (0.1–0.3MPa)121/2 standardValvola pressione

Loading...

  1. 1

Informazioni di base

Tipo Valvole a farfalla Profilo corpo principale Doppio Metodo di controllo Misurazione Uscita/Ingresso
Tipo giunto Filettatura maschio + attacchi a innesto rapido Materiale corpo principale PBT Ambiente d'esercizio, applicazioni Standard
Materiale filettatura Acciaio inox (EN 1.4305 Equiv.) Con manopola Resina Gamma di pressioni d'esercizio(MPa) null::1.0
Types of Screw R Sealing Method Con guarnizione

Si trova sulla pagina di ASR*30 / ASQ*30, valvola di risparmio aria (valvola PFC / QFC) , sistema metrico, il codice articolo è il seguente: ASR630F-04-12S.
Ulteriori dettagli concernenti specifiche e dimensioni si trovano sotto il codice prodotto ASR630F-04-12S.

Tipologia prodotto

Codice componente
ASQ430F-02-06S-F20
ASQ430F-02-08S
ASQ430F-02-08S-F20
ASQ430F-02-10S
ASQ430F-02-10S-F20
ASR630F-04-12S-F20
Codice componentePrezzo unitario standardQuantità minima d'ordineSconto volumi elevatiGiorni
spedizione standard
?
Opzione controdado Temperature ambiente e fluido
(°C)
Connection Dia. Option Applicable Tube O.D. mm
(mm)
Body Size Classificazione del prodotto

31.94 €

1 26 giorni blocco a forma dado-5~ 601/4Pressione regolata fissa (0.2MPa)61/4 standardValvola flusso

35.39 €

1 Stesso giorno

Stock

blocco a forma dado-5~601/4Pressione regolata variabile (0.1–0.3MPa)81/4 standardValvola flusso

31.94 €

1 26 giorni blocco a forma dado-5~ 601/4Pressione regolata fissa (0.2MPa)81/4 standardValvola flusso

35.39 €

1 4 giorni blocco a forma dado-5~601/4Pressione regolata variabile (0.1–0.3MPa)101/4 standardValvola flusso

31.94 €

1 26 giorni blocco a forma dado-5~ 601/4Pressione regolata fissa (0.2MPa)101/4 standardValvola flusso

49.21 €

1 39 giorni blocco a forma dado-5~ 601/2Pressione regolata fissa (0.2MPa)121/2 standardValvola pressione

Supporto tecnico