ZQ, unità compatta eiettore per il vuoto

ZQ, unità compatta eiettore per il vuoto
Easy-to-use vacuum pressure switch.
[Features]
· Push button type for easier operation.
· Vacuum pressure switch with LED display.
· Can copy up to 10 switches simultaneously.
· Settings for the master side (copy source) sensor can be copied to slave side sensors.
· Reduced setting work.
· Helps prevent setting mistakes.

(i)Nota

  • Le immagini del prodotto sono solo immagini rappresentative. Fare riferimento al catalogo del produttore per i dettagli sulla forma.

Codice componente

Qui sono indicati i codici componente
correlati al prodotto ricercato

Space Saving Vacuum Ejector ZQ Series Specifications

Space Saving Vacuum Ejector ZQ Series external appearance 1

Space Saving Vacuum Ejector ZQ Series external appearance 1

Space Saving Vacuum Ejector ZQ Series external appearance 2

Space Saving Vacuum Ejector ZQ Series external appearance 2

Ejector Specifications

Model ZQ105 ZQ107 ZQ110
Nozzle Diameter (mm) 0.5 0.7 1.0
Maximum Suction Flow Rate L/min (ANR) 5 10 22
Air Consumption L/min (ANR) 14 23 46
Maximum Vacuum Pressure -80 kPa
Supply Pressure Range Air Pressure Supply
(P) Port
0.3 to 0.5 MPa
(For normally open type: 0.3 to 0.45 MPa)
Release Pressure Supply
(PD) Port
0.3 to 0.5 MPa
(For normally open type: 0.3 to 0.45 MPa)
And PD pressure ≥ P pressure
Standard Supply Pressure Note: 0.35 MPa 0.43 MPa
Operating Temperature Range 5 to 50°C
Usable Fluids Air

Note: The maximum suction flow rate was obtained at the standard supply pressure.

Product Weight

  • With suction filter (single unit): 95 g (*1)
  • With vacuum pressure switch + suction filter (single unit): 109 g (*2)
  • End plate assembly for manifold: 122 g
  • *1 Includes 0.3-m connector for supply valve and release valve.
  • *2 Includes a 0.3‑m connector for supply valve and release valve and a 2‑m connector for vacuum pressure switch.

Manifold Type Weight Calculation

(Unit weight) ×; number of stations + (weight of end plate assembly for manifold)
Example: Eight stations with a vacuum pressure switch and suction filter
109 g ×; 8 + 122 g = 994 g

Product Supply And Release Valves

Type Normally Closed Type Latching Type Normally Open Type
Standard Type (1 W) Low Wattage Type (0.5 W)
Model (Refer to the section on ordering solenoid valves on p. 107) VQ110-□ VQ110Y-□ VQ110L-□
VQ110N-□
ZQ1-VQ120-□
Manual Operation Non-locking push type / locking type (tool required) Push-lock type Non-locking push type / locking type (tool required)
Coil Rated Voltage 12/24 V DC, 100/110/200/220 V AC 12/24 V DC 12/24 V DC, 100/110/200/220 V AC 12/24 V DC
Power Consumption (Current Value) DC 1 W 0.5 W 1 W
AC 100 V 0.5 VA (5 mA) - 0.6 VA (6 mA) -
110 V AC 0.55 VA (5 mA) - 0.65 VA (5.9 m) -
200 V AC 1.0 VA (5 mA) - 1.2 VA (6 mA) -
220 V AC 1.1 VA (5 mA) - 1.3 VA (5.9 mA) -
Electrical Entry Grommet,
L-type plug connector (with light / surge voltage suppressor)
L-type plug connector
(With light / surge voltage suppressor)
Grommet,
L-type plug connector
(With light / surge voltage suppressor)

Vacuum Pressure Switch Specifications

Model ZQ1-ZSE (ZSE10) ZQ1-ZSE (ZSE10F)
Rated Pressure Range 0 to -101 kPa -100 to 100 kPa
Set Pressure Range / Display Pressure Range 10 to -105 kPa -105 to 105 kPa
Withstand Pressure 500 kPa
Minimum Setting Unit 0.1 kPa
Power Supply Voltage 12 to 24 V DC ±10%, ripple (p-p) 10% or less (with power supply polarity protection)
Current Consumption 40 mA or less
Switch Output - NPN or PNP open collector 2 outputs (selectable)
Maximum Load Current 80 mA
Maximum Applied Voltage 28 V (with NPN output)
Residual Voltage 2 V or less (with load current of 80 mA)
Response Time 2.5 ms or less (with anti-chattering function: 20, 100, 500, 1,000, 2,000 ms selectable)
Short Circuit Protection Equipped
Repeatability ±0.2% F.S. ±1 digit
Hysteresis Hysteresis Mode Variable from 0 Note 1:
Window Comparator Mode
Analog Output Voltage Output Output Voltage (Rated Pressure Range) 1 to 5 V ±2.5% F.S.
Linearity ±1% F.S. or less
Output Impedance Approx. 1 k Ω
Display System 3 1/2-digit, 7-segment LED, 1 color display (red)
Display Accuracy ±2% F.S. ±1 digit (with ambient temperature of 25°C ±3°C)
Operation Indicator Light Lights when ON, OUT1: green, OUT2: red
Environmental Resistance Enclosure IP40
Operating Humidity Range Operating/stored: 35 to 85% RH (no condensation)
Withstand Voltage 1,000 V AC for 1 min. between live parts and housing
Insulation Resistance 50 MΩ or more (500 V DC measured with megohmmeter) between live parts and housing
Temperature Characteristics ±2% F.S. (at 25°C of operating temperature range: -5 to +50°C)
Lead Wires Oil-resistant cabtire cord
Conductor cross-sectional area: 0.15 mm2 (AWG26), 5 cores, 2 m, insulator outer diameter: 1.0 mm

Note 1: If the applied voltage fluctuates around the set value, the hysteresis must be set to a value more than the width of the fluctuations or chattering will occur.
Note 2: For specifications not listed, ejector specifications apply.

Product Exhaust Characteristics

ZQ105 exhaust characteristics

ZQ105 exhaust characteristics

ZQ107 exhaust characteristics

ZQ107 exhaust characteristics

ZQ110 exhaust characteristics

ZQ110 exhaust characteristics

Single Unit and Manifold Structural Drawing / Components and Replacement Parts

Single unit structural drawing

Single unit structural drawing

Manifold structural drawing

Manifold structural drawing

Components

Number Part Name Material
1 Poppet Valve Assembly -
2 Nozzle Resin
3 Diffuser Resin
4 Vacuum Break Flow Adjusting Needle Stainless steel

Replacement Parts

Number Part Name Material Part number
5 Solenoid valve - Refer to p. 107 for details
6 Filter Element PVA sponge XT534-5-001-AS
7 Sound absorption material 1 (for single units) PVA sponge ZQ-SAE
8 Vacuum Pressure Switch - Refer to p. 107 for details
9 Fitting - -
10 Sound absorption material 2 (for manifolds) PVA sponge ZZQ-SAE

Product Drawings

 

(Unit: mm)

 

J1 Type ZQ1□1U-J1□□□□-□□□□□-□□

J1 type ZQ1□1U-J1□□□□-□□□□□-□□ dimensional drawing

J1 type ZQ1□1U-J1□□□□-□□□□□-□□ dimensional drawing

 
J1 type ZQ1□1U-J1□□□□-□□□□□-□□ circuit diagram

J1 type ZQ1□1U-J1□□□□-□□□□□-□□ circuit diagram

Note 1: Drawing is of the ZQ1□1U-J1□5/6L-E□□G□-00. For the ZQ1□1U-J1□□□□-F□-00, the overall length is 87.2 mm.
Note 2: The dimensions after bracket A is mounted are the same as those of the K1 type.
Note 3: When mounting the body, tighten to a torque of 0.6 ±0.06 N·m. Using excessive torque may cause damage to the body.
Note 4: For the ZQ series, the pitches of the P, V and PE ports are determined assuming the use of one-touch fittings.
If used with other fittings, these may cause interference, dependent on their type and size. Refer to the manufacturer's catalog to confirm the sizes of the fittings before use.

Manifold Type Increase/Decrease Method

Manifold Type Increase/Decrease Method

Manifold Type Increase/Decrease Method

Components

Number Part Name Part Number
1 Hexagon Socket Head Cap Screw See the section on ordering below
2 End Block L See Table 1 (includes (6) × 1 pc.)
3 End Block R See Table 1 (includes (5) × 1 pc.)
4 Ejector Assembly ZQ1□□3M-□□□□□□-□□□□□-□(-Q) Note 1:
(Includes (5) and (6) × 1 of each)
5 Ejector Body Gasket for Manifolds ZQ-3-005-10AS Note 2:
6 Gasket for Exhaust Block ZQ-3-009-10AS Note 2:

Note 1: Refer to pp. 102–103 of the manufacturer's catalog for details on ordering.
Note 2: This part number is a 10-piece set.

Table 1

Part Name With PD Port Without PD Port
End Block L ZQ1L-2-BSB-AS ZQ1L-1-BSB-AS
End Block R ZQ1R-2-BSB-AS ZQ1R-1-BSB-AS

Working Procedure

Disassembly

Loosen and remove clamp rod (1).

Assembly

  • 1. Install the ejector body gasket for manifolds (5) into the gasket groove of each ejector assembly (4). Install the exhaust block gasket (6) around the projected part.
  • 2. Install the exhaust block gasket (6) around the projected part of end block L (2).
  • 3. Install the ejector body gasket for manifolds (5) into the gasket groove of end block R (3).
  • 4. Align the ejector assembly (4), end block L (2) and end block R (3) using locating pins (at the 2 'a' positions) and fasten with the clamp rods (1) (× 2 pcs.) (Tightening torque: 0.6 N·m ±0.06 N·m)

*Refer to the manufacturer's catalog for product information not detailed above.

Codice componente
ZQ1101U-K1Y5L-EBG-00-Q
ZQ1101U-K15L-EBG-00-Q
Codice componente
Prezzo unitario standard
Quantità minima d'ordineSconto volumi elevati
Giorni
spedizione standard
?
Gamma di temperature di esercizio
(°C)
Staffa A Funzione

384.69 €

1 39 giorni 5:50~-DC tipo a bassa potenza (0.5W)

383.15 €

1 39 giorni 5~ 50Con staffa ATipo standard (1 W per DC)

Loading...

  1. 1

Informazioni di base

Tipo Unità Funzione aggiuntiva Silenziatori / Filtro Vuoto finale(kPa) -80
Portata consumo di aria(L/min) 46 Profilo attacco di collegamento apertura vuoto M5 Profilo attacco di collegamento porta di mandata aria M5
Categoria di funzionamento Tipo normalmente chiuso Applicazione Elemento singolo Gamma di pressioni d'esercizio(MPa) 0.3::0.5
Flusso di aspirazione(L/min) 22 Diam. ugello 1.0mm Combinazione di valvola di mandata e valvola di rilascio Normalmente chiuso / normalmente chiuso
Ingresso elettrico Connettore spina tipo L, lunghezza conduttore: 0.3m (con LED / circuito di protezione) Specifiche uscita Collettore aperto PNP 2 uscite (0 – -101KPa) Specifiche unità Con funzione di soluzione unità
Tensione nominale elettrovalvola 24V DC Ingresso elettrico interruttore per vuoto Conduttore con connettore (lunghezza conduttore: 2m), con copertura connettore Con contrassegno CE Con contrassegno CE
Tipo valvola No Disinnesto manuale Tipo di dispositivo a pressione senza blocco

Supporto tecnico