IZD10, Sensore Elettrostatico

IZD10, Sensore Elettrostatico
Electrostatic sensor that detects the electrostatic potential of a workpiece and outputs in analog voltage.
[Features]
· Confirming the actual status is important when managing static electricity.
· Can be used for a wide-range of electrostatic potential measurement applications.
· Compact and easy to mount.
· RoHS compliant.
· Installation distance (IZD10-110) 10 to 50 mm (±0.4 kV at an installation distance of 25 mm).
· Installation distance (IZD10-510) 25 to 75 mm (±20 kV at an installation distance of 50 mm).

(i)Nota

  • Please refer to the manufacturer's catalog for specification details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

Codice componente

Qui sono indicati i codici componente
correlati al prodotto ricercato

Electrostatic Sensor, IZD10 Series Specifications

Electrostatic Sensor Type IZD10-110 IZD10-510
Potential Measurement ±0.4 kV (detection range at 25 mm)* ±20 kV (detection range at 50 mm)*
Output Voltage 1 to 5 V (Output impedance: Approx. 100Ω)
Effective Detection Distance 10 to 50 mm 25 to 75 mm
Linearity ±5% F.S. (0 to 50°C, at detection distance of 25 mm) ±5%F.S. (0 to 50°C, at detection distance of 50 mm)
Output Delay Time 100 ms or less
Power Supply Voltage 21.6 to 26.4 V DC (Within 24 V DC ±10%)
Current Consumption 40 mA or less
Ambient Operating Temperature 0 to 50°C
Ambient Humidity 35 to 85% Rh (with no condensation)
Material Head case: ABS, Amplifier case: ABS
Vibration Resistance Durability 50 Hz, Amplitude 1 mm, X, Y, Z: 2 hours each
Impact Resistance 100 m/s2
Weight 185 g (including cable weight)
Compliance with EN Standards Protective Class: Class III (EN60950-1)
Pollution Degree 3
CE Marking: Low voltage directive: 2006/95/EC
Only when connected to a SELV-type external circuit
EMC Directive 2004/108/EC
UL Standard UL508

*The measured potential and output voltage varies depending on the detection distance. For details of the relationship between measured potentials and output voltages according to detection distance, refer to the "Output Signal" graphs in the Technical Data section of the catalog.

Connection Circuit and Wiring Table

Connect the lead wires according to the connection circuit and wiring table.

IZD10 Series connection circuit

IZD10 Series connection circuit

Lead Wire Coating Color Description Function
Brown DC (+) Power supply 24 V DC
Blue DC (-) Power Supply 0 V
White Sensor output Analog output for 1 to 5 V
  • *Ensure grounding. Ensure GND terminal is grounded with a ground resistance of 100Ω or less. Also, a dedicated power supply is recommended for the sensor-driving power supply. Connecting any equipment other than the sensor to this power supply may trigger the malfunctioning or breakdown of the equipment when static electricity is discharged to the sensor head or when noise enters the GND terminal.
    *When using the cable on the external equipment connection side after cutting it short, do not connect a shielding wire (since the shielding wire is a common wire with the amplifier case, provide a frame ground on the amplifier case side).
  • *Text in ( ) refers to the lead wire coating color of the dedicated cable.

Dimensional Outline Drawing

 

(Unit: mm)

 

IZD10-110/IZD10-510 dimensional drawing 1

IZD10-110/IZD10-510 dimensional drawing 1

 

(Unit: mm)

 

IZD10-110/IZD10-510 dimensional drawing 2

IZD10-110/IZD10-510 dimensional drawing 2

 

(Unit: mm)

 

IZD10-110/IZD10-510 dimensional drawing 3

IZD10-110/IZD10-510 dimensional drawing 3

Output Signal

When measuring the potential of a charged object with an electrostatic sensor, the relationship between the electrostatic potential being measured and the output voltage varies depending on the sensor's installation distance. The relationship between the electrostatic sensor's output voltage and the detected electrostatic potential depending on the installation distance is as shown in the figure below. (The installation distance in the figure refers to the distance between the object being measured and the electrostatic sensor.)

Relationship between Sensor Output Voltage and Electrostatic Potential at Each Installation Distance

IZD10-110 electrostatic potential graph

IZD10-110 electrostatic potential graph

IZD10-510 electrostatic potential graph

IZD10-510 electrostatic potential graph

Detection Range

IZD10 Series detection range

IZD10 Series detection range

IZD10 Series part names

IZD10 Series part names

IZD10-110 (Potential Measurement ±0.4 kV)

Installation Range (mm) Detection Range (mm)
10 45
20 85
25 100
30 120
40 150
50 180

IZD10-510 (Potential Measurement ±20 kV)

Installation Range (mm) Detection Range (mm)
25 100
30 120
40 150
50 180
60 205
70 225
75 235

Specific Product Precautions

  • *Product images are representative images. These images may differ from the actual products.
  • *Refer to the catalog for further information.
Codice componente
IZD10-110
IZD10-510
Codice componente
Prezzo unitario standard
Quantità minima d'ordineSconto volumi elevati
Giorni
spedizione standard
?
Potenziali misurati

431.27 €

1 4 giorni ±0.4kV (gamma di rilevamento a 25mm)

431.27 €

1 4 giorni ±20kV (gamma di rilevamento a 50mm)

Loading...

  1. 1

Informazioni di base

Tipo Dispositivi di misurazione antistatici Indicatori Non in dotazione Funzione aggiuntiva Non in dotazione
Funzione di regolazione bilanciamento ioni Non in dotazione Alimentazione 24 V DC

Supporto tecnico