ARM1000 / 2000, regolatore serie manifold

ARM1000 / 2000, regolatore serie manifold
Manifold regulator with 4 connection methods.
[Features]
· Small size pressure gauge ø15 (diameter 15 mm).
· Standard models are equipped with a backflow function.
· Space saving.
· Fluid: air.
· Guaranteed pressurance resistance: 1.2 MPa.
· Maximum operating pressure: 0.8 MPa.
· Set pressure range (standard): 0.05 to 0.7 MPa.
· Set pressure range (0.2 MPa setting): 0.05 to 0.2 MPa.

(i)Nota

  • ■ SMC Product Line
    Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.
    Click here for a quotation or to make an order if you have a model number.

    ■ Products Planned for Online Release
    Air cylinder-related product pages will be released on this site on an ad-hoc basis.
    CQ2, MG types, etc., are already available. Click here to check.
    *Vacuum equipment, FRLs, solenoid valves, etc., will also be released on dedicated pages on this site on an ad-hoc basis.
    *The information above is correct as of December 2018.
  • See the catalog for specification details.
  • Product images may be representative images. Refer to the catalog for details.

Codice componente

Qui sono indicati i codici componente
correlati al prodotto ricercato

ARM1000/2000 Series Manifold Regulator Specifications

ARM2000-4B2 external appearance

ARM2000-4B2 external appearance

ARM2000-4A2-01G external appearance

ARM2000-4A2-01G external appearance

Common IN (left) / individual IN (right) JIS symbols

Common IN (left) / individual IN (right) JIS symbols

Conceptual diagram of connection variants

Conceptual diagram of connection variants

Ambient and fluid temperature -5 to +60°C (no freezing)
Fluid Air
Cracking pressure (valve) 0.02 MPa
Structure Relieving type

Port Size / Weight

Model Piping specifications Connection port size Weight (g)
IN side OUT side Total weight (n: stations) Regulator (except manifold)
ARM1000 Common IN 1/8 1/8 (80 ×; n) + 23 57
Individual IN 1/8 1/8 (79 ×; n) +25
ARM2000 Common IN 1/4 1/8 (188 ×; n) +43 136
Individual IN 1/8 1/8 (187 ×; n) +45

Diagram (Individual IN)

Individual IN Diagram

Individual IN Diagram

Number Part name Material Note
1 Main body Die-cast aluminum Chromate treatment
2 Manifolds Aluminum alloy Chromate treatment
3 Valve guide Brass -
4 Piston Brass -
5 Pressure regulator spring Steel wire Zinc chromate
6 Adjusting screw Structural steel Electroless nickel plating
Number Part name Material
7 Valve Brass, HNBR
8 Valve spring Stainless steel
9 Valve retainer Polyacetal
10 O-ring NBR
11 O-ring NBR

Setting

  • 1.Make sure to check the inlet pressure before setting the outlet pressure. Turning the pressure adjustment handle clockwise increases the outlet pressure and turning it counterclockwise decreases the pressure. (To set the pressure, do so in the direction of pressure)
  • 2.The outlet pressure range must be 85% or less than the inlet pressure.

Flow Characteristics (Representative Values)

Conditions: inlet pressure = 0.7 MPa

ARM1000 flow rate characteristics graph

ARM1000 flow rate characteristics graph

ARM2000 flow rate characteristics graph

ARM2000 flow rate characteristics graph

Pressure Characteristics (Representative Values)

Conditions (initial settings): inlet pressure 0.7 MPa, outlet pressure 0.2 MPa, flow rate 10 L/min (ANR)

ARM1000 pressure characteristics graph

ARM1000 pressure characteristics graph

ARM2000 pressure characteristics graph

ARM2000 pressure characteristics graph

Dimensions

 

(Unit: mm)

 

ARM1000/2000 Series dimensional drawing

ARM1000/2000 Series dimensional drawing

External Dimensions Table

 

(Unit: mm)

 

Model Symbol
A B C D E F G H J K M P Q R
ARM1000 4.5 25 34 21 18 56 16 9 18 19 52 9 11.5 4.8
ARM2000 4.5 34.5 43 28 27 70 20 11.5 24 28 66 11.5 16.5 4.8

Dimensions by the Number of Stations

 

(Unit: mm)

 

Model Symbol Manifold stations (n)
1 2 3 4 5 6 7 8 9 10
ARM1000 L1 36 55 74 93 112 131 150 169 188 207
L2 27 46 65 84 103 122 141 160 179 198
ARM2000 L1 48 76 104 132 160 188 216 244 272 300
L2 39 67 95 123 151 179 207 235 263 291

Precautions

Mounting/Adjustment

  • *In the case of the common IN type, supply pressure from the two IN ports from both ends. Failure to observe this procedure could lead to an excessive pressure drop.
  • *Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.
    Lock operating method
    Loosen the handle locking nut to release the lock, and tighten it to lock it.
  • *The attached reverse flow mechanism is placed between the electromagnetic valve and actuator and can be used as a check regulator.

Maintenance

  • *Make sure to perform a periodic inspection of the pressure gauge when it is used by installing it between a solenoid valve and an actuator, etc. Because of the possibility of creating sudden pressure fluctuations, the durability of the product could be shortened. Under certain circumstances, the use of an electronic type pressure gauge is recommended.

Other precautions

  • *Be sure to read the safety precautions as well as the common precautions in the manufacturer's catalog before use.
  • *The images for this product are representative images. *The product shown may differ from the actual product.
  • *See the manufacturer's catalog for information other than the above.
Codice componente
ARM1000-1A1-01
ARM1000-1A1-01G
ARM1000-1B1-01
ARM1000-1B1-01-1
ARM1000-1B1-01G
ARM1000-1B2-01
ARM1000-1B2-01G
ARM1000-2A1-01G
ARM1000-2A1-N01G
ARM1000-2A2-01
ARM1000-2A2-01G
ARM1000-2B1-01
ARM1000-2B1-01G
ARM1000-2B1-01G-1
ARM1000-2B2-01-1
ARM1000-2B2-01G
ARM1000-3A1-01
ARM1000-3A1-01G
ARM1000-3A2-01G
ARM1000-3B1-01
ARM1000-3B1-01G
ARM1000-3B2-01
ARM1000-3B2-01G
ARM1000-3B2-01G-1
ARM1000-4A1-01
ARM1000-4A1-01G
ARM1000-4A1-01G-1
ARM1000-4A2-01G
ARM1000-4B1-01
ARM1000-4B1-01G
ARM1000-4B1-01G-1
ARM1000-4B2-01G
ARM1000-4B2-01G-1
ARM1000-5A1-01
ARM1000-5A1-01G
ARM1000-5A1-01G-1
ARM1000-5B1-01
ARM1000-5B1-01G
ARM1000-6A1-01
ARM1000-6A1-01G
ARM1000-6B1-01G
ARM1000-6B2-01
ARM1000-6B2-01G
ARM1000-7A1-01
ARM1000-7A1-01G
ARM1000-7B1-01
ARM1000-7B1-01G
ARM1000-7B2-01G
ARM1000-8A1-01
ARM1000-8A1-01G
ARM1000-8B1-01G
ARM1000-9A1-01G
ARM1000-9B1-01G
ARM1000-9B2-01
ARM1000-10A1-01
ARM1000-10A1-01G
ARM1000-10B1-01
ARM1000-10B1-01G
ARM1000-10B2-01
ARM2000-1A1-01
Codice componente
Prezzo unitario standard
Quantità minima d'ordineSconto volumi elevati
Giorni
spedizione standard
?
Lato mandata, tipo di collegamento Lato mandata, diam. collegamento Lato controllo, tipi di collegamento Manometro Size of Body Set Pressure Connected Number Piping Specification

22.48 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa1 stazioneIN: comune, OUT: lato collettore

30.39 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa1 stazioneIN: comune, OUT: lato collettore

23.63 €

1 4 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7 MPa1 stazioneIN: individuale, OUT: lato collettore

27.18 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.2MPa1 stazioneIN: individuale, OUT: lato collettore

31.52 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa1 stazioneIN: individuale, OUT: lato collettore

23.63 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa1 stazioneIN: singolo, OUT: lato corpo

31.52 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa1 stazioneIN: singolo, OUT: lato corpo

62.98 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPaTipo doppioIN: comune, OUT: lato collettore

62.98 €

1 26 giorni [NPT] NPT1/8[NPT] NPT[Con manometro] Con manometro1,0000.05–0.7MPaTipo doppioIN: comune, OUT: lato collettore

47.19 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPaTipo doppioIN: comune, OUT: lato corpo

62.98 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPaTipo doppioIN: comune, OUT: lato corpo

48.27 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPaTipo doppioIN: individuale, OUT: lato collettore

64.06 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7 MPaTipo doppioIN: individuale, OUT: lato collettore

64.06 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.2MPaTipo doppioIN: individuale, OUT: lato collettore

27.18 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.2MPaTipo doppioIN: singolo, OUT: lato corpo

64.08 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPaTipo doppioIN: singolo, OUT: lato corpo

71.85 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPaTipo triploIN: comune, OUT: lato collettore

95.48 €

1 31 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7 MPaTipo triploIN: comune, OUT: lato collettore

95.47 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPaTipo triploIN: comune, OUT: lato corpo

72.94 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPaTipo triploIN: individuale, OUT: lato collettore

96.56 €

1 4 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7 MPaTipo triploIN: individuale, OUT: lato collettore

72.94 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPaTipo triploIN: singolo, OUT: lato corpo

96.56 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPaTipo triploIN: singolo, OUT: lato corpo

96.50 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.2MPaTipo triploIN: singolo, OUT: lato corpo

96.50 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa4 stazioniIN: comune, OUT: lato collettore

127.97 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa4 stazioniIN: comune, OUT: lato collettore

127.97 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.2MPa4 stazioniIN: comune, OUT: lato collettore

127.97 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa4 stazioniIN: comune, OUT: lato corpo

97.69 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa4 stazioniIN: individuale, OUT: lato collettore

129.18 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa4 stazioniIN: individuale, OUT: lato collettore

129.18 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.2MPa4 stazioniIN: individuale, OUT: lato collettore

129.18 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa4 stazioniIN: singolo, OUT: lato corpo

129.18 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.2MPa4 stazioniIN: singolo, OUT: lato corpo

121.21 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa5 stazioniIN: comune, OUT: lato collettore

160.58 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa5 stazioniIN: comune, OUT: lato collettore

178.18 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.2MPa5 stazioniIN: comune, OUT: lato collettore

122.29 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa5 stazioniIN: individuale, OUT: lato collettore

161.66 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa5 stazioniIN: individuale, OUT: lato collettore

145.87 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa6 stazioniIN: comune, OUT: lato collettore

193.06 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa6 stazioniIN: comune, OUT: lato collettore

194.19 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa6 stazioniIN: individuale, OUT: lato collettore

147.02 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa6 stazioniIN: singolo, OUT: lato corpo

194.19 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa6 stazioniIN: singolo, OUT: lato corpo

170.58 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa7 stazioniIN: comune, OUT: lato collettore

225.56 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa7 stazioniIN: comune, OUT: lato collettore

171.66 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa7 stazioniIN: individuale, OUT: lato collettore

226.65 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa7 stazioniIN: individuale, OUT: lato collettore

226.65 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa7 stazioniIN: singolo, OUT: lato corpo

195.24 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa8 stazioniIN: comune, OUT: lato collettore

258.10 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa8 stazioniIN: comune, OUT: lato collettore

259.24 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa8 stazioniIN: individuale, OUT: lato collettore

290.65 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa9 stazioniIN: comune, OUT: lato collettore

291.73 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa9 stazioniIN: individuale, OUT: lato collettore

221.03 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa9 stazioniIN: singolo, OUT: lato corpo

244.53 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa10 stazioniIN: comune, OUT: lato collettore

323.08 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa10 stazioniIN: comune, OUT: lato collettore

245.74 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa10 stazioniIN: individuale, OUT: lato collettore

324.27 €

1 26 giorni Rc1/8Rc[Con manometro] Con manometro1,0000.05–0.7MPa10 stazioniIN: individuale, OUT: lato collettore

245.74 €

1 26 giorni Rc1/8Rc[Non in dotazione] N/A1,0000.05–0.7MPa10 stazioniIN: singolo, OUT: lato corpo

26.94 €

1 26 giorni Rc1/4Rc[Non in dotazione] N/A20000.05–0.7MPa1 stazioneIN: comune, OUT: lato collettore

Loading...

Informazioni di base

Regolatore, valvola di sovrapressione Regolatore Regolatore Profilo a collettore Liquido applicabile Aria
Profilo Standard Ambiente d'esercizio Standard Meccanismo di scarico Sfiato
Funzione corrente contraria Disponibile Gamma di pressioni d'esercizio(MPa) null::0.8 Lato di controllo, diametro collegamento 1/8

Supporto tecnico