Codice articolo del costruttore: IDHA6-23B
Marca: SMC
Prezzo: 6,127.40 €
Tempi di consegna: 68 giorni
Volume aria di processo [classificazione]: Fino a 1000 L/min
Volume aria di processo: 600 L/min
Misura compressore pneumatico: 5.5 kW
Power Supply Voltage: Monofase 230V AC 50/60Hz
Auto drain: Assente
Codice componente
Qui sono indicati i codici componente
correlati al prodotto ricercato
IDHA6-23B
IDH□ Series external appearance
Size
Structure Principle Diagram (Air/Refrigerant Circuit)
Hot and humid air entering this product is cooled down by the cooler. The moisture condensed at this time is separated by the drain separator and exhausted automatically. The pressure of the dry air is adjusted by the regulator, and oil mist and solid particles are separated by the micro mist separator with pre-filter and super mist separator. The temperature of the dry and high-purity air is adjusted by the heater, and the air is supplied to the outlet side.
*The type without filter is not applicable.
The HFC gas contained in the refrigerant circuit is compressed by the compressor, and cooled and liquefied by the condenser. When passing through the capillary tube, the HFC gas is regulated and its temperature decreases. While passing through the cooler part, it evaporates rapidly, taking the heat from the compressed air, and is sucked in by the compressor. The capacity regulating valve opens when the compressed air has been cooled sufficiently, and prevents condensed water from being frozen by excessive cooling.
Specifications | Model | ||||||
---|---|---|---|---|---|---|---|
IDH4-10□ | IDH4-20□ | IDHA4-23□ | IDH6-10□ | IDH6-20□ | IDHA6-23□ | ||
Operating range*3 | Applicable fluid | Compressed Air | |||||
Air flow capacity*1 | 100 to 500 L/min (ANR) | 200 to 800 L/min (ANR) | |||||
Inlet air temperature | 5 to 40°C | ||||||
Inlet air pressure | 0.3 to 1.0 MPa | ||||||
Ambient temperature | 15 to 35°C (Relative humidity 85% or less) | ||||||
Outlet air temperature adjustment range*2 | 15 to 30°C | ||||||
Outlet air set pressure range | 0.15 to 0.85 MPa (The inlet air pressure should be at least 0.15 MPa higher than the outlet air pressure.) | ||||||
Rated conditions | Air flow capacity | 400 L/min (ANR) | 600 L/min (ANR) | ||||
Inlet air pressure | 0.7 MPa | ||||||
Inlet air temperature | 35°C | ||||||
Ambient temperature | 30°C | ||||||
Outlet air set temperature | 30°C | ||||||
Rated performance*4 | Outlet air pressure dew point | 10°C | |||||
Outlet air temperature stability*5 | ±0.1°C (This may vary depending on the conditions.) | ||||||
Outlet air temperature display accuracy | ±0.5°C (including accuracy of the sensor) | ||||||
Electric specifications | Power supply*6 | Single-phase 100 V AC (50/60 Hz) | Single-phase 200 V AC (50/60 Hz) | Single-phase 230 V AC (50/60 Hz) | Single-phase 100 V AC (50/60 Hz) | Single-phase 200 V AC (50/60 Hz) | Single-phase 230 V AC (50/60 Hz) |
Operating current | 4.2 A | 2.1 A | 2.1 A | 9.4 A | 4.8 A | 4.8 A | |
Earth leakage breaker capacity | 10 A | 5 A | 5 A | 15 A | 10 A | 10 A | |
Compressor input | 180/200 W 50/60 Hz | 385/440 W 50/60 Hz | |||||
Heater input | 220 W | 420 W | |||||
Built-in filter specifications*7 | Nominal filtration rating | 0.01 μm (99.9% filtration efficiency) | |||||
Cleanliness of the filter outlet side | Particles of 0.3 μm or more: 3.5 particles/L (ANR) or less | ||||||
Temperature control method | Heater operation, PID control | ||||||
Refrigerant type / Refrigerant charge | R134a / 0.14 kg | R134a / 0.26 kg | |||||
Noise level (reference value)*8 | 52 dB (A) | 55 dB (A) | |||||
Weight | 26 kg | 37 kg | |||||
Applicable drain tube O.D. | 10 mm | ||||||
Coating color | Body panel: urban white 1, Base: urban gray 2 | ||||||
Compliant standards | CE marked |
*1: ANR is the value at 20°C, atmospheric pressure and relative humidity 65%.
*2: About 10 minutes are required until the temperature becomes stable after setting the temperature.
*3: The upper limit of the settable outlet air temperature varies depending on the conditions even within the operating range. Be sure to read the selection document before selecting the models.
*4: The rated performance is the performance when the operation of each part is stable without fluctuations in operating conditions and power supply. If the air flow capacity is beyond its specified range or if the air flows intermittently, the outlet air temperature range or temperature stability may not be satisfied. (If this happens, install a purge line and flow the compressed air continuously.)
*5: When the outlet air temperature is set in the range of the ambient temperature ±5°C.
*6: Keep the voltage within -5 to +10% of the rated voltage. If there is voltage fluctuation, the outlet air temperature stability may decrease. So if highly accurate temperature adjustment is required, use a stable power supply to make the voltage fluctuation smaller.
*7: The specification changes depending on the cleanliness of the inlet side air. It may take time until the cleanliness of the filter outlet side air stabilizes immediately after start of operation. The filter performance only applies to the built-in type filter.
*8: 1 m in front of the product, 1 m in height, without load, stable conditions.
Output signal timing chart
Description | Terminal No. | Description of operation | Contact capacity | Minimum load |
---|---|---|---|---|
Operating signal N.O. (a-contact) | 1-2 | Close after 10 minutes of operation | Resistance load 2 A Inductive load 80 VA Lamp load 100 W | 5 V DC 2 mA |
Error signal N.C. (b contact) | 3-4 | Open at an emergency stop or set temperature error | ||
Error signal N.O. (a-contact) | 4-5 | Close at an emergency stop or set temperature error |
*1: The operation can be started or restarted (manually) by the operation stop switch mounted on the thermo-dryer or a remote switch prepared by the user.
*2: When an emergency stop is generated 5 times in an hour or the heater protection equipment (thermostat) is activated, the emergency stop status will be held. In this case, the dryer can be restarted by the reset operation using the switch stated in *1.
(Unit: mm)
Dimensional drawing: IDH□4
(Unit: mm)
Dimensional drawing: IDH□6
Condensed water calculation chart
Example: To obtain the amount of condensed water when the pressure is applied to air up to 0.7 MPa with an air compressor, then cooled down to 25°C, with an ambient temperature of 30°C and a relative humidity of 60%.
(Per 1 m3) Amount of moisture at intersection C - amount of moisture at intersection H = amount of condensed water or 18.2 - 3 = 15.2 g/m3
Dew point conversion chart
(Example) To obtain the atmospheric pressure dew point at a pressure dew point of 10°C and a pressure of 0.7 MPa.
*See the manufacturer's catalog for product information other than the above.
Codice componente
|
---|
IDHA6-23B |
Codice componente |
Prezzo unitario standard
| Quantità minima d'ordine | Sconto volumi elevati | Volume aria di processo [classificazione] (L/min) | Volume aria di processo (L/min) | Misura compressore pneumatico (kW) | Power Supply Voltage | Auto drain | Filtro | |
---|---|---|---|---|---|---|---|---|---|---|
6,127.40 € | 1 | 68 giorni | Fino a 1000 | 600 | 5.5 | Monofase 230V AC 50/60Hz | Assente | Nessuno |
Loading...
Tipo | Essiccatore | Metodo | Refrigerazione (specifiche per raffreddamento ad aria) | Profilo | Standard |
---|---|---|---|---|---|
Punto di rugiada della pressione atmosferica dell'aria in uscita(°C) | 10 | Lato mandata, tipo di collegamento | Rc | Temperatura aria su porta di ingresso(°C) | 35 |
Pressione aria su lato porta di ingresso(MPa) | 0.7 | Lato di mandata, designazione nominale filettatura tubazione | 1/2 | Lato controllo, tipi di collegamento | Rc |
Filettatura tubo nominale lato di controllo | 1/2 |
Si trova sulla pagina di IDH, Thermo-dryer, il codice articolo è il seguente: IDHA6-23B.
Ulteriori dettagli concernenti specifiche e dimensioni si trovano sotto il codice prodotto IDHA6-23B.
Configura
Proprietà di base
Tipo
Volume aria di processo [classificazione](L/min)
Volume aria di processo(L/min)
Power Supply Voltage
Auto drain
Filtro
Filtrare per tipo dati CAD
Filtrare per giorni di spedizione standard
Attributi opzionali
Codice componente |
---|
IDH6-10 |
IDH6-20 |
IDH6-20-E |
IDHA4-23 |
IDHA4-23-E |
IDHA6-23B-E |
Codice componente | Prezzo unitario standard | Quantità minima d'ordine | Sconto volumi elevati | Giorni spedizione standard ? | Volume aria di processo [classificazione] (L/min) | Volume aria di processo (L/min) | Misura compressore pneumatico (kW) | Power Supply Voltage | Auto drain | Filtro |
---|---|---|---|---|---|---|---|---|---|---|
6,312.39 € | 1 | 26 giorni | Fino a 1000 | 600 | 5.5 | Monofase 100 V AC 50/60 Hz | Assente | Filtro (AMH) + Filtro (AME) | ||
6,312.39 € | 1 | 26 giorni | Fino a 1000 | 600 | 5.5 | Monofase 200 V AC 50/60 Hz | Assente | Filtro (AMH) + Filtro (AME) | ||
6,324.14 € | 1 | 68 giorni | Fino a 1000 | 600 | 5.5 | Monofase 200 V AC 50/60 Hz | Scarico automatico (normalmente chiuso) | Filtro (AMH) + Filtro (AME) | ||
5,153.00 € | 1 | 4 giorni | Fino a 400 | 400 | 3.7 | Monofase 230V AC 50/60Hz | Assente | Filtro (AMH) + Filtro (AME) | ||
5,162.37 € | 1 | 68 giorni | Fino a 400 | 400 | 3.7 | Monofase 230V AC 50/60Hz | Scarico automatico (normalmente chiuso) | Filtro (AMH) + Filtro (AME) | ||
6,136.79 € | 1 | 26 giorni | Fino a 1000 | 600 | 5.5 | Monofase 230V AC 50/60Hz | Scarico automatico (normalmente chiuso) | Nessuno |