Codice articolo del costruttore: IRV20-LC08
Marca: SMC
Prezzo: 103.74 €
Tempi di consegna: 4 giorni
Flusso di utilizzo: 240 L/min
Lato di mandata, diametro tubo di collegamento: Ø8
Diametro tubo di collegamento lato di controllo: Ø8
Specifiche tubazioni: Collegamenti standard
Profilo raccordo lato mandata: Gomito
Codice componente
Qui sono indicati i codici componente
correlati al prodotto ricercato
IRV20-LC08
Model | IRV10 | IRV20 | |
---|---|---|---|
Usable fluids | Air | ||
Set pressure rangeNote 1) | -100 to -1.3 kPa | ||
Withstand pressureNote 2) | 100 kPa (except with pressure gauge) | ||
Atmospheric intake consumptionNote 3) | 0.6 L/min (ANR) or less | ||
Knob resolution | 0.13 kPa or less | ||
Ambient and fluid temperature | 5 to 60°C | ||
VAC side tubing outer diameter | ø6 (diameter 6 mm), ø8 (diameter 8 mm) ø1/4" (diameter 1/4" mm), ø5/16" (diameter 5/16" mm) | ø6 (diameter 6 mm), ø8 (diameter 8 mm), ø10 (diameter 10 mm) ø1/4" (diameter 1/4" mm), ø5/16" (diameter 5/16" mm), ø3/8" (diameter 3/8" mm) | |
SET side tubing outer diameter | |||
Weight (without accessories) | Standard connections | 135 g (IRV10-C08) | 250 g (IRV20-C10) |
Single-sided connections | 125 g (IRV10A-C08) | 250 g (IRV20A-C10) |
Note 1) Varies depending on the pressure of the vacuum pump.
Note 2) Supplying positive pressure to vacuum regulators equipped with a pressure gauge may damage the pressure gauge. Application of positive pressure will not damage the vacuum regulator; however, the main valve will open and positive pressure will enter the vacuum pump, which may cause malfunction of the vacuum pump. When using the vacuum regulator in a suction transport system, etc., refer to the following piping example so as to avoid supplying positive pressure to the vacuum pump. This vacuum regulator is not capable of adjusting positive pressure.
Note 3) Constantly intakes the atmospheric air.
Structural Diagram
Working Principle
When the knob is turned to the right (clockwise), the adjusting spring’s generated force pushes down the diaphragm and the valve. This connects the VAC side and SET side, and the degree of vacuum on the SET side increases (becomes closer to an absolute vacuum).
Furthermore, the SET side vacuum pressure moves through the air passage into the vacuum chamber, where it is applied to the top side of the diaphragm and counters the adjusting spring’s compression force; and this adjusts the SET side pressure. When the degree of vacuum on the SET side is higher than the designated setting value (becomes closer to an absolute vacuum), the balance between the adjusting spring and the SET side pressure in the vacuum chamber is lost, and the diaphragm is pushed up. This causes the valve to close and the atmospheric intake valve to open, which lets atmospheric air into the SET side. When the adjusting spring’s compression force and the SET side pressure are balanced, the SET side pressure is set. Also, when the degree of vacuum of the SET side pressure is lower than the designated setting value (becomes closer to the atmosphere), the balance between the adjusting spring and the vacuum chamber is lost, and the diaphragm is pushed down.
This causes the atmospheric intake valve to close and the valve to open, which lets air into the VAC side. When the adjusting spring's compression force and the SET side pressure are balanced, the SET side pressure is set.
(Unit: mm)
IRV10: Standard Connections Drawing
Fitting part dimensions
(Unit: mm)
Fitting size | VAC/SET | |||
---|---|---|---|---|
Straight | Elbow | Elbow | Elbow | |
R | S | T | U | |
ø6 (diameter 6 mm), ø1/4" (diameter 1/4" mm) | 10 | 19 | 26 | 3 |
ø8 (diameter 8mm), ø5/16" (diameter 5/16" mm) | 12 | 20 | 28 | 6 |
IRV10-□□□Z (N/P/A/B): drawing with digital pressure switch
Fitting part dimensions
(Unit: mm)
Fitting size | VAC/SET | |||
---|---|---|---|---|
Straight | Elbow | Elbow | Elbow | |
R | S | T | U | |
ø6 (diameter 6 mm), ø1/4" (diameter 1/4" mm) | 10 | 19 | 26 | 3 |
ø8 (diameter 8mm), ø5/16" (diameter 5/16" mm) | 12 | 20 | 28 | 6 |
(Unit: mm)
IRV10A-□□□G: drawing with pressure gauge
Fitting part dimensions
(Unit: mm)
Fitting size | VAC/SET | ||||
---|---|---|---|---|---|
Straight | Elbow | Elbow | Elbow | Elbow | |
R | S | T | U | V | |
ø6 (diameter 6 mm), ø1/4" (diameter 1/4" mm) | 10 | 19 | 26 | 7.5 | 11 |
ø8 (diameter 8mm), ø5/16" (diameter 5/16" mm) | 12 | 20 | 28 | 10.5 | 14 |
(Unit: mm)
IRV10A-□□□Z (N/P/A/B): drawing with digital pressure switch
Fitting part dimensions
(Unit: mm)
Fitting size | VAC/SET | ||||
---|---|---|---|---|---|
Straight | Elbow | Elbow | Elbow | Elbow | |
R | S | T | U | V | |
ø6 (diameter 6 mm), ø1/4" (diameter 1/4" mm) | 10 | 19 | 26 | 7.5 | 11 |
ø8 (diameter 8mm), ø5/16" (diameter 5/16" mm) | 12 | 20 | 28 | 10.5 | 14 |
*Please refer to the manufacturer's catalog for other models and specifications.
Codice componente
|
---|
IRV20-LC08 |
Codice componente |
Prezzo unitario standard
| Quantità minima d'ordine | Sconto volumi elevati | Flusso di utilizzo (L/min) | Lato di mandata, diametro tubo di collegamento | Diametro tubo di collegamento lato di controllo | Specifiche tubazioni | Profilo raccordo lato mandata | Profilo raccordo lato controllo | |
---|---|---|---|---|---|---|---|---|---|---|
103.74 € | 1 | 4 giorni | 240 | Ø8 | Ø8 | Collegamenti standard | Gomito | Gomito |
Loading...
Tipo | Regolatore vuoto | Metodo di controllo | Lineare | Profilo | Standard |
---|---|---|---|---|---|
Lato mandata, tipo di collegamento | Tubo ad azione singola | Lato controllo, tipi di collegamento | Tubo ad azione singola | Gamma di pressioni regolate(kPa) | -100::-1.3 |
Accessori | No | Specifiche personalizzate | No | Staffa | No |
Si trova sulla pagina di IRV10 / 20, Regolatore per vuoto, il codice articolo è il seguente: IRV20-LC08.
Ulteriori dettagli concernenti specifiche e dimensioni si trovano sotto il codice prodotto IRV20-LC08.
Configura
Proprietà di base
Tipo
Flusso di utilizzo(L/min)
Lato di mandata, diametro tubo di collegamento
Diametro tubo di collegamento lato di controllo
Specifiche tubazioni
Profilo raccordo lato mandata
Profilo raccordo lato controllo
Filtrare per tipo dati CAD
Filtrare per giorni di spedizione standard
Attributi opzionali
Codice componente |
---|
IRV10-LC08 |
IRV10A-C06 |
IRV10A-C08 |
IRV20-LC10 |
IRV20A-C06 |
IRV20A-C08 |
Codice componente | Prezzo unitario standard | Quantità minima d'ordine | Sconto volumi elevati | Giorni spedizione standard ? | Flusso di utilizzo (L/min) | Lato di mandata, diametro tubo di collegamento | Diametro tubo di collegamento lato di controllo | Specifiche tubazioni | Profilo raccordo lato mandata | Profilo raccordo lato controllo |
---|---|---|---|---|---|---|---|---|---|---|
99.92 € | 1 | 4 giorni | 140 | Ø8 | Ø8 | Collegamenti standard | Gomito | Gomito | ||
101.81 € | 1 | 4 giorni | 140 | Ø6 | Ø6 | Specifica collegamento lato singolo | Dritto | Dritto | ||
101.81 € | 1 | 20 giorni | 140 | Ø8 | Ø8 | Specifica collegamento lato singolo | Dritto | Dritto | ||
103.74 € | 1 | 4 giorni | 240 | Ø10 | Ø10 | Collegamenti standard | Gomito | Gomito | ||
105.65 € | 1 | 4 giorni | 240 | Ø6 | Ø6 | Specifica collegamento lato singolo | Dritto | Dritto | ||
105.65 € | 1 | 4 giorni | 240 | Ø8 | Ø8 | Specifica collegamento lato singolo | Dritto | Dritto |