VNC (solenoide), valvola per refrigerante, azionamento pneumatico, solenoide con pilota esterno (Codici componente - Download CAD)

VNC (solenoide), valvola per refrigerante, azionamento pneumatico, solenoide con pilota esterno
A coolant valve made by SMC.
[Features]
· Cylinder actuation by pilot air
· Wide selection of port sizes and variations
· Low water hammer
· Large valve capacity

(i)Nota

  • Le immagini dei prodotti possono essere immagini rappresentative. Fare riferimento al catalogo per i dettagli.

Codice componente

Qui sono indicati i codici componente
correlati al prodotto ricercato

External Pilot Type Solenoid Valve, Air Operated Type, Coolant Valve VNC Series Specifications

VNC Series external appearance 1

VNC Series external appearance 1

VNC Series external appearance 2

VNC Series external appearance 2

Fluid (Main Piping) Coolant *2
Fluid Temperature VNC□□□A
VNC□1□B
*1: -5 to +60°C
VNC□0□B *1: -5 to +99℃
Ambient Temperature *1: -5 to +50°C (60°C for air-operated type)
Proof Pressure 1.5 MPa
Operating Pressure Range VNC□□1□ 0 to 0.5 MPa
VNC□□2□
VNC□□4□
0 to 1 MPa
External
Pilot
Air
Pressure VNC□□1□
VNC□□4□
0.25 to 0.7 MPa
VNC□□2□ 0.1 + 0.25 ×; (operating pressure) to 0.7 MPa
*See table 1
Lubrication Not required (if lubricating, use turbine oil class 1 ISO VG32)
Temperature *1: -5 to +50°C (60°C for air-operated type)
Mounting Orientation *3: Unrestricted

*1 No freezing.
*2: This product cannot be used for water.
*3: However, if the external pilot is a solenoid type, SMC recommends mounting the pilot solenoid valve in an upward facing vertical or horizontal orientation.

Table 1: VNC□□2□ pilot pressure (N.O. type)

Table 1: VNC□□2□ pilot pressure (N.O. type)

Model

Model Piping Connection Port Diameter Orifice Diameter ø[mm] Flow Rate Characteristics Weight (kg)
Thread Flange* Kv Conversion Cv Air Operated Type External Pilot Solenoid Type
VNC1□□□-6A 1/8 - 7 1.1 1.2 0.2 0.3
VNC1□□□-8A 1/4 - 1.1 1.3
VNC1□□□-10A 3/8 - 1.3 1.5
VNC2□4□-10A 11 3.4 3.9 0.5 0.7
VNC2□□□-10A 15 4.3 5.0
VNC2□4□-15A 1/2 - 11 3.9 4.5
VNC2□□□-15A 15 5.0 5.8
VNC3□4□-20A 3/4 - 14 6.1 7.0 0.8 1.0
VNC3□□□-20A 20 9.3 11
VNC4□4□-25A 1 - 16 7.9 9.1 1.2 1.4
VNC4□□□-25A 25 13.2 15
VNC5□4□-32A 1 1/4 - 22 14.3 17 2.2 2.4
VNC5□□□-32A 32 20.0 23
VNC5□4□-32F - 32 22 14.3 17 5.0 5.2
VNC5□□□-32F 32 20.0 23
VNC6□4□-40A 1 1/2 - 28 22.5 26 3.6 3.8
VNC6□□□-40A 40 29.3 34
VNC6□4□-40F - 40 28 25.7 30 6.8 7.0
VNC6□□□-40F 40 34.3 40
VNC7□4□-50A 2 - 33 35.4 41 5.5 5.7
VNC7□□□-50A 50 53.6 62
VNC7□4□-50F - 50 33 35.7 41 10.2 10.4
VNC7□□□-50F 50 57.1 66
VNC814□-65F - 65 45 42.4 49 - 15.7
VNC811□-65F 65 60.6 70
VNC914□-80F - 80 56 63.1 73 - 21.2
VNC911□-80F 80 86.5 100

Product Dimensions

Thread

 

(Units: mm)

 

Piping connection: 6A, 8A, 10A dimensional drawing

Piping connection: 6A, 8A, 10A dimensional drawing

*9 mm longer for EZ, TZ and DZ.

  • VNC1□□□-6A: Main port 1, 2 / 1/8
  • VNC1□□□-8A: Main port 1, 2 / 1/4
  • VNC1□□□-10A: Main port 1, 2 / 3/8

 

(Units: mm)

 

Piping connection: 10A, 15A, 20A, 25A dimensional drawing

Piping connection: 10A, 15A, 20A, 25A dimensional drawing

 

(Units: mm)

 

Model Main Port 1, 2 A B C D E F H J* K L M N P Q R S
VNC2□□□-10A 3/8 63 42 29 14.5 72.5 80.5 95.3 162.5 (164.5) 52 26 4.5 24.3 2.3 25 34 55
VNC2□□□-15A 1/2 63 42 29 14.5 72.5 80.5 95.3 162.5 (164.5) 52 26 4.5 24.3 2.3 25 34 55
VNC3□□□-20A 3/4 80 50 35 17.5 84 92 100.3 174 (176) 62 31 5.5 28.3 2.3 30 43 60.5
VNC4□□□-25A 1 90 60 40 20 100 108 101.3 190 (192) 72 36 6.5 33.3 2.3 35 49 73

*The dimensions in ( ) are for CE compliant products (-Q).

Product Diagram

N.C. (spring return normally closed type) diagram

N.C. (spring return normally closed type) diagram

When pilot solenoid valve 8 is not energized (or when air is exhausted from 12 (P1) port of the air operated type), valve 4 linked to piston 6 is closed via the action of the return spring 7.

For Opening the Valve

When the pilot solenoid valve is energized (or when pressurized air enters through port 12 (P1) of the air operated type), the pilot air that has entered under the piston moves upward, opening the valve.

For Closing the Valve

When the power to the pilot solenoid valve is cut (or when fluid is exhausted from port 12 (P1) of the air operated type), the pilot air under the piston is exhausted and the valve closed via the action of the return spring.

N.O. (spring return normally open type) diagram

N.O. (spring return normally open type) diagram

In contrast for the N.C. type, when the power to the pilot solenoid valve is shut off (or when air is exhausted from port 10 (P2) of the air operated type), unenergized, the valve is held open via the return spring.
When the pilot solenoid valve is energized (or when pressurized air enters through port 10 (P2) of the air operated type), the valve closes.

Number Part Name Material Notes
1 Body Assembly Cast iron Plated
2 Cover Assembly Aluminum alloy Platinum silver coated
3 Plate Assembly Iron Seal material (NBR, FKM)
4 Valve Element Stainless steel -
5 Valve Cover NBR, FKM 32A to 50A use an O-ring
6 Piston Assembly Aluminum alloy -
7 Return Spring Piano wire -
8 Spiral Pin Stainless steel -
9 Pilot Solenoid Valve - -

*Parts 3 and 5 are for selection of valve composition.

Precautions

  • *Use heat resistant parts for fittings and tubing when using high temperature fluids. (Compression fittings, fluorine resin tubes, copper piping, etc.)
  • *Be sure to read the individual product precautions before use.
  • *See the SMC catalog for product information other than the above.
Codice componente
VNC102A-6A
VNC102A-6A-B
VNC102A-F8A
VNC112A-8A-5D-Q
VNC202A-10A
VNC202A-15A
VNC212A-15A-5D-Q
VNC302A-20A
VNC302A-20A-B
VNC302A-F20A
VNC402A-25A
VNC402B-25A
VNC412A-25A-5D-Q
VNC412A-25A-5DZ-Q
VNC412B-25A-5D-Q
VNC502A-F32A
VNC512A-F32A-5DZ-Q
VNC602A-40A
VNC612A-40A-5DZ-Q
VNC702A-50A
VNC702A-F50A
VNC712A-50A-5DZ-Q
VNC712B-50A-7DZ-Q
Codice componente
Prezzo unitario standard
Quantità minima d'ordineSconto volumi elevati
Giorni
spedizione standard
?
Tipo A commutazione Tipo di collegamento Filettatura tubazione nominale Misura nominale flangia tubo Diam. orifizio
(Ø)
Gamma di temperature di esercizio
(°C)
Tensione Materiali di tenuta Opzione Staffa Funzioni Conformità CE Ingresso elettrico conduttore

86.90 €

1 26 giorni Funzionamento ad ariaNormalmente aperto[Rc (R)] Rc1/8-7-5~ 60-NBRAssenteAssenteAssente-Assente

89.69 €

1 26 giorni Funzionamento ad ariaNormalmente aperto[Rc (R)] Rc1/8-7-5~ 60-NBRAssenteInclusoAssente-Assente

86.90 €

1 26 giorni Funzionamento ad ariaNormalmente apertoG1/4-7-5~ 60-NBRAssenteAssenteAssente-Assente

120.29 €

1 26 giorni Tipo elettromagneticoNormalmente aperto[Rc (R)] Rc1/4-7-5~5024V DCNBRAssenteAssenteProdotto con conformità CE-Terminale DIN

110.98 €

1 26 giorni Funzionamento ad ariaNormalmente aperto[Rc (R)] Rc3/8-15-5~ 60-NBRAssenteAssenteAssente-Assente

110.98 €

1 26 giorni Funzionamento ad ariaNormalmente aperto[Rc (R)] Rc1/2-15-5~ 60-NBRAssenteAssenteAssente-Assente

176.10 €

1 26 giorni Tipo elettromagneticoNormalmente aperto[Rc (R)] Rc1/2-15-5~5024V DCNBRAssenteAssenteProdotto con conformità CE-Terminale DIN

137.69 €

1 26 giorni Funzionamento ad ariaNormalmente aperto[Rc (R)] Rc3/4-20-5~ 60-NBRAssenteAssenteAssente-Assente

145.81 €

1 26 giorni Funzionamento ad ariaNormalmente aperto[Rc (R)] Rc3/4-20-5~ 60-NBRAssenteInclusoAssente-Assente

137.71 €

1 26 giorni Funzionamento ad ariaNormalmente apertoG3/4-20-5~ 60-NBRAssenteAssenteAssente-Assente

164.44 €

1 26 giorni Funzionamento ad ariaNormalmente aperto[Rc (R)] Rc1-25-5~ 60-NBRAssenteAssenteAssente-Assente

176.53 €

1 26 giorni Funzionamento ad ariaNormalmente aperto[Rc (R)] Rc1-25-5~ 60-FKMAssenteAssenteAssente-Assente

233.87 €

1 26 giorni Tipo elettromagneticoNormalmente aperto[Rc (R)] Rc1-25-5~5024V DCNBRAssenteAssenteProdotto con conformità CE-Terminale DIN

232.65 €

1 26 giorni Tipo elettromagneticoNormalmente aperto[Rc (R)] Rc1-25-5~5024V DCNBRLuceAssenteProdotto con conformità CE-Terminale DIN con spia e circuito di protezione

245.90 €

1 26 giorni Tipo elettromagneticoNormalmente aperto[Rc (R)] Rc1-25-5~5024V DCFKMAssenteAssenteProdotto con conformità CE-Terminale DIN

344.84 €

1 26 giorni Funzionamento ad ariaNormalmente apertoG1 1/4-32-5~ 60-NBRAssenteAssenteAssente-Assente

425.56 €

1 26 giorni Tipo elettromagneticoNormalmente apertoG1 1/4-32-5~5024V DCNBRLuceAssenteProdotto con conformità CE-Terminale DIN con spia e circuito di protezione

387.60 €

1 26 giorni Funzionamento ad ariaNormalmente aperto[Rc (R)] Rc1 1/2-40-5~ 60-NBRAssenteAssenteAssente-Assente

468.32 €

1 26 giorni Tipo elettromagneticoNormalmente aperto[Rc (R)] Rc1 1/2-40-5~5024V DCNBRLuceAssenteProdotto con conformità CE-Terminale DIN con spia e circuito di protezione

477.16 €

1 26 giorni Funzionamento ad ariaNormalmente aperto[Rc (R)] Rc2-50-5~ 60-NBRAssenteAssenteAssente-Assente

477.16 €

1 26 giorni Funzionamento ad ariaNormalmente apertoG2-50-5~ 60-NBRAssenteAssenteAssente-Assente

557.82 €

1 26 giorni Tipo elettromagneticoNormalmente aperto[Rc (R)] Rc2-50-5~5024V DCNBRLuceAssenteProdotto con conformità CE-Terminale DIN con spia e circuito di protezione

579.23 €

1 26 giorni Tipo elettromagneticoNormalmente aperto[Rc (R)] Rc2-50-5~50-FKMLuceAssenteProdotto con conformità CE-Terminale DIN con spia e circuito di protezione

Loading...

  1. 1

Informazioni di base

Liquido applicabile Refrigerante Ambiente d'esercizio Standard Tipo di azionamento Con pilota
Numero di solenoidi Solenoide singolo Applicazione Elemento singolo Materiale corpo Ghisa
Funzionamento manuale Senza blocco, a pressione

Supporto tecnico