Elettrovalvole a 5 vie / metriche / pilotate, tenuta resiliente, VFR3000 (VFR3200-5FZ-02-Q)

Elettrovalvole a 5 vie / metriche / pilotate, tenuta resiliente, VFR3000 VFR3200-5FZ-02-Q

Dettagli del prodotto:

Codice articolo del costruttore: VFR3200-5FZ-02-Q

Marca: SMC

Prezzo: 237.90

Tempi di consegna: 26 giorni


Dati Tecnici:

Tipo: Elettrovalvole

Applicazione: Uso singolo

Numero di attacchi: Valvola a 5 porte

Metodo di installazione: Diretto

Caratteristiche: Standard / Senza lubrificazione


(i)Nota

  • Product images may be representative. Refer to the manufacturer's catalog for details.

Codice componente

Qui sono indicati i codici componente
correlati al prodotto ricercato

VFR3200-5FZ-02-Q

Rubber Seal, 5-Port Pilot Type, Plug-In Type / Non-Plug-In Type VFR3000 Series Specifications

VFR3000 Series plug-in type external appearance

VFR3000 Series plug-in type external appearance

VFR3000 Series non-plug-in type external appearance

VFR3000 Series non-plug-in type external appearance

Valve Specifications Fluid Air
Operating pressure range 2 position single, 3 position 0.2 to 0.9 MPa
2-position double 0.1 to 0.9 MPa
Ambient Temperature and Operating Fluid Temperature -10°C to +50°C (no freezing).
Lubrication Not required *1
Manual Operation Non-locking, push type
Mounting Orientation Free
Impact Resistance / Vibration Resistance 300/50 m/s2 *2
Enclosure Dust-proof
Electrical Specifications Coil Rated Voltage 100 V, 200 V AC (50/60 Hz), 24 V DC
Allowable Voltage Fluctuation -15% to +10% of rated voltage
Apparent Power AC *3 Starting 5.6 VA / 50 Hz, 5.0 VA / 60 Hz
Holding 3.4 VA (2.1 W) / 50 Hz, 2.3 VA (1.5 W) / 60 Hz
Current Consumption DC *3 1.8 W (2.04 W: with light and surge voltage suppressor)
Electrical Entry Plug-in type Conduit terminal
Non-plug-in type Grommet, grommet terminal
Conduit terminal, DIN terminal

*1: If lubricating, use turbine oil class 1 (ISO VG32).
*2: Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunctions occurred in a 1-sweep test between 45 and 2,000 Hz. The test was performed in both energized and non-energized states and in the axial direction and at right angles to the main valve and armature. (Initial value)
*3: At rated voltage.

Model

Configuration Model Piping Connection Port Diameter *1 Flow Rate Characteristics *1
Plug-In Non-Plug-In 1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB)
C
(dm3/(s·bar))
b Cv C
(dm3/(s·bar))
b Cv
2 Position Single VFR310□ VFR311□
VFR314□
1/4 7.5 0.38 1.9 7.5 0.34 1.9
3/8 8.4 0.39 2.2 8.7 0.38 2.2
Double VFR320□ VFR321□
VFR324□
1/4 7.1 0.41 1.9 7.4 0.40 1.9
3/8 7.9 0.36 2.0 8.6 0.37 2.2
3 Position Closed Center VFR330□ VFR331□
VFR334□
1/4 6.8 0.40 1.8 6.3 0.38 1.6
3/8 7.2 0.39 1.9 6.5 0.40 1.7
Exhaust Center VFR340□ VFR341□
VFR344□
1/4 6.5 0.42 1.7 7.9 (3.4) 0.41 (0.47) 2.0 (0.96)
3/8 6.9 0.42 1.8 9.5 (3.4) 0.39 (0.46) 2.4 (0.96)
Pressure Center VFR350□ VFR351□
VFR354□
1/4 7.6 (2.4) 0.33 (0.48) 1.9 (0.69) 6.1 0.36 1.5
3/8 9.3 (2.4) 0.34 (0.47) 2.2 (0.69) 6.5 0.41 1.7
Configuration Model Maximum Operating Frequency Hz *2 Response Time ms *3 Weight (kg) *4
Plug-In Non-Plug-In
2 Position Single VFR310□ VFR311□
VFR314□
5 30 or less 0.61 (0.64) [0.58]
Double VFR320□ VFR321□
VFR324□
5 30 or less 0.71 (0.74) [0.69]
3 Position Closed Center VFR330□ VFR331□
VFR334□
3 50 or less 0.72 (0.75) [0.71]
Exhaust Center VFR340□ VFR341□
VFR344□
3 50 or less 0.72 (0.75) [0.71]
Pressure Center VFR350□ VFR351□
VFR354□
3 50 or less 0.72 (0.75) [0.71]

*1: Values in [ ] denote the normal position.
*2: The minimum operating frequency is once per 30 days.
*Based on JIS B 8419:2010 dynamic performance test (at 0.5 MPa, with coil temperature of 20°C, at rated voltage, with no surge voltage suppressor).
*4: The table shows values for the VFR3□00-□FZ-02/03. Values in ( ) are for the VFR3□10-□DZ-02/03, and the values in [ ] are for the VFR3□40-□G-02/03.

Product Drawing

Non-plug-in type / 2-position single

 

(Unit: mm)

 

2-Position position single: VFR3140/1-□G dimensional drawing

2-Position position single: VFR3140/1-□G dimensional drawing

  • *Values in ( ) are for 1/4.

 

(Unit: mm)

 

E: grommet terminal dimensional drawing

E: grommet terminal dimensional drawing

  • *The numbers in boxes are for with a light and surge voltage suppressor.

 

(Unit: mm)

 

T: Conduit terminal dimensional drawing

T: Conduit terminal dimensional drawing

  • *The numbers in boxes are for with a light and surge voltage suppressor.

 

(Unit: mm)

 

D, Y: DIN terminal dimensional drawing

D, Y: DIN terminal dimensional drawing

  • *The numbers in boxes are for with a light and surge voltage suppressor.

Non-plug-in type / 2-position double, 3-position closed center, exhaust center, pressure center

 

(Unit: mm)

 

2-position double: VFR3240/1-□G, 3-position closed center: VFR3340/1-□G, 3-position exhaust center: VFR3440/1-□G, 3-position pressure center: VFR3540/1-□G dimensional drawing

2-position double: VFR3240/1-□G, 3-position closed center: VFR3340/1-□G, 3-position exhaust center: VFR3440/1-□G, 3-position pressure center: VFR3540/1-□G dimensional drawing

  • Values in brackets are for position 3.
  • Values in parentheses are for 1/4.

 

(Unit: mm)

 

E: grommet terminal dimensional drawing

E: grommet terminal dimensional drawing

  • Values in brackets are for position 3.
  • *The numbers in boxes are for with a light and surge voltage suppressor.

 

(Unit: mm)

 

T: Conduit terminal dimensional drawing

T: Conduit terminal dimensional drawing

  • Values in brackets are for position 3.
  • *The numbers in boxes are for with a light and surge voltage suppressor.

 

(Unit: mm)

 

D, Y: DIN terminal dimensional drawing

D, Y: DIN terminal dimensional drawing

  • Values in brackets are for position 3.
  • *The numbers in boxes are for with a light and surge voltage suppressor.

Precautions

  • Be sure to read the individual product cautions before use.
  • See the SMC catalog for product information other than that detailed above.
Codice componente
VFR3200-5FZ-02-Q
Codice componente
Prezzo unitario standard
Quantità minima d'ordineSconto volumi elevati
Giorni
spedizione standard
?
Tipo Applicazione Numero di attacchi Metodo di installazione Caratteristiche Numero di solenoidi A commutazione Stato allo spegnimento Tensione Tipo di attacco tubo Filettatura tubazione nominale Diam. cilindro applicabile
(Ø)
Tubazioni Tipo di azionamento Valore CV Con tenuta Pressione nominale
(MPa)
Mandata aria pilota Interruttore manuale Ingresso elettrico conduttore Manuale Spia / circuito di protezione Conformità CE Tipo corpo Specifiche tubazioni Opzioni corpo Related component type

237.90 €

1 26 giorni ElettrovalvoleUso singoloValvola a 5 porteDirettoStandard / Senza lubrificazioneTipo doppio2 posizioni, scaricoRitegno automatico24 V DC[Rc (R)] Rc1/440–140Tubatura sottobaseStelo pilota1.9Guarnizione morbida0.1–0.9CircuitoSenza bloccaggioTerminale condotto a innestoSenza blocco, a pressioneCon spia e circuito di protezioneA innestoRaccordo lateraleStandard-

Loading...

  1. 1

Si trova sulla pagina di Elettrovalvole a 5 vie / metriche / pilotate, tenuta resiliente, VFR3000, il codice articolo è il seguente: VFR3200-5FZ-02-Q.
Ulteriori dettagli concernenti specifiche e dimensioni si trovano sotto il codice prodotto VFR3200-5FZ-02-Q.

Tipologia prodotto

Codice componente
VFR3100-1FZ-Q
VFR3100-3FZ-Q
VFR3100-3FZC-Q
VFR3200-5FZ-03-Q
VFR3200-5FZ-03N-Q
VFR3200-5FZ-B02-Q
Codice componentePrezzo unitario standardQuantità minima d'ordineSconto volumi elevatiGiorni
spedizione standard
?
Tipo Applicazione Numero di attacchi Metodo di installazione Caratteristiche Numero di solenoidi A commutazione Stato allo spegnimento Tensione Tipo di attacco tubo Filettatura tubazione nominale Diam. cilindro applicabile
(Ø)
Tubazioni Tipo di azionamento Valore CV Con tenuta Pressione nominale
(MPa)
Mandata aria pilota Interruttore manuale Ingresso elettrico conduttore Manuale Spia / circuito di protezione Conformità CE Tipo corpo Specifiche tubazioni Opzioni corpo Related component type

139.18 €

1 26 giorni ElettrovalvoleUnità di montaggio collettoreValvola a 5 porteBase collettoreStandard / Senza lubrificazione[Tipo singolo] Tipo singolo2 posizioni, scaricoAutoreset (ritorno molla)100 V AC---Tubatura sottobaseStelo pilota-Guarnizione morbida02–0.9CircuitoSenza bloccaggioTerminale condotto a innestoSenza blocco, a pressioneCon spia e circuito di protezioneA innesto-Standard-

139.18 €

1 26 giorni ElettrovalvoleUnità di montaggio collettoreValvola a 5 porteBase collettoreStandard / Senza lubrificazione[Tipo singolo] Tipo singolo2 posizioni, scaricoAutoreset (ritorno molla)110–120V AC---Tubatura sottobaseStelo pilota-Guarnizione morbida02–0.9CircuitoSenza bloccaggioTerminale condotto a innestoSenza blocco, a pressioneCon spia e circuito di protezioneA innesto-Standard-

139.18 €

1 26 giorni ElettrovalvoleUnità di montaggio collettoreValvola a 5 porteBase collettoreStandard / Senza lubrificazione[Tipo singolo] Tipo singolo2 posizioni, scaricoAutoreset (ritorno molla)110–120V AC---Tubatura sottobaseStelo pilota-Guarnizione morbida02–0.9CircuitoBloccoTerminale condotto a innestoTipo bloccabile (leva)Con spia e circuito di protezioneA innesto-Standard-

237.90 €

1 26 giorni ElettrovalvoleUso singoloValvola a 5 porteDirettoStandard / Senza lubrificazioneTipo doppio2 posizioni, scaricoRitegno automatico24 V DC[Rc (R)] Rc3/840–200Tubatura sottobaseStelo pilota2Guarnizione morbida0.1–0.9CircuitoSenza bloccaggioTerminale condotto a innestoSenza blocco, a pressioneCon spia e circuito di protezioneA innestoRaccordo lateraleStandard-

237.77 €

1 26 giorni ElettrovalvoleUso singoloValvola a 5 porteDirettoStandard / Senza lubrificazioneTipo doppio2 posizioni, scaricoRitegno automatico24 V DCNPT3/840–200Tubatura sottobaseStelo pilota2Guarnizione morbida0.1–0.9CircuitoSenza bloccaggioTerminale condotto a innestoSenza blocco, a pressioneCon spia e circuito di protezioneA innestoRaccordo lateraleStandard-

247.53 €

1 26 giorni ElettrovalvoleUso singoloValvola a 5 porteDirettoStandard / Senza lubrificazioneTipo doppio2 posizioni, scaricoRitegno automatico24 V DC[Rc (R)] Rc1/440–140Tubatura sottobaseStelo pilota1.9Guarnizione morbida0.1–0.9CircuitoSenza bloccaggioTerminale condotto a innestoSenza blocco, a pressioneCon spia e circuito di protezioneA innestoCon uscita inferioreStandard-

Supporto tecnico