Codice articolo del costruttore: XLD-40L-M9//
Marca: SMC
Prezzo: 1,060.13 €
Tempi di consegna: 22 giorni
Ghiere con flangia: 40
Conduttanza sonica: 45L/S
Direzione porta pilota: Superficie flangia, posteriore
Codice componente interruttore: Senza interruttore automatico (con magnete incorporato)
Codice componente
Qui sono indicati i codici componente
correlati al prodotto ricercato
XLD-40L-M9//
XLD Series external appearance
XLD Series operating port direction
Model | XLD-25 | XLD-40 | XLD-50 | XLD-63 | XLD-80 | |
---|---|---|---|---|---|---|
Valve Type | Always closed (spring return and seal) (both main and initial exhaust valves) | |||||
Fluids | Inert gas vacuum | |||||
Operating Temperature (°C) | XLD | 5 to 60 (5 to 150 for high temperature type) | ||||
Operating Pressure Pa (abs) | 1 ×; 10-6 to atmospheric pressure | |||||
Conductance L/s Note 1: | Main Exhaust Valve | 14 | 45 | 80 | 160 | 200 |
Initial Exhaust Valve | 0.5 to 3 | 2 to 8 | 2.5 to 11 | 4 to 18 | 4 to 18 | |
Amount of leakage Pa·m3/s | Internal | For standard material (FKM): 1.3 ×; 10-10, values at normal temperature and excluding gas permeation | ||||
External | For standard material (FKM): 1.3 ×; 10-11, values at normal temperature and excluding gas permeation | |||||
Flange Type | KF (NW) | KF (NW) / K (DN) | ||||
Main Material Note 3: | Main body: aluminum alloy, Bellows: SUS316L, Main parts: stainless steel, FKM (standard sealing material) | |||||
Surface Treatment | External: hard anodized aluminum, Internal: base material | |||||
Pilot Pressure MPa (G) | 0.4 to 0.7 (both main and initial exhaust valves) | |||||
Pilot Port Connection Port Diameter | XLD | M5 | Rc 1/8 | |||
Weight (kg) | XLD | 0.5 | 1.2 | 1.8 | 3.4 | 5.6 |
Note 1: The main exhaust valve conductance is the value for the "molecular flow" of an elbow with the same dimensions. The initial exhaust valve conductance is the "viscous flow" value.
Note 2: For valve heater specifications, see "Common Option (1) Heater" in the manufacturer's catalog.
Note 3: A coating of vacuum grease (Y-VAC2) has been applied to the seal-material sliding section (initial exhaust valve sliding part) of the vacuum part.
XLD air-operated type dimensional drawing
(Unit: mm)
Model | A | B | C | D | E | Fn | Fd | G | H | J | K |
---|---|---|---|---|---|---|---|---|---|---|---|
XLD-25 | 50 | 123 | 48 | 1 | 12 | 40 | - | 26 | 41 | 16 | 7.5 |
XLD-40 | 65 | 170 | 66 | 2 | 11 | 55 | - | 41 | 63 | 20 | 15 |
XLD-50 | 70 | 183 | 79 | 2 | 11 | 75 | - | 52 | 68 | 20 | 17.5 |
XLD-63 | 88 | 217 | 100 | 3 | 11 | 87 | 95 | 70 | 72 | 20 | 20 |
XLD-80 | 90 | 256 | 117 | 3 | 11 | 114 | 110 | 83 | 98 | 20 | 26.5 |
Note 1: Dimension E applies when heater option is included. (Lead wire length: approx. 1 m)
Note 2: A, B, and C in the figure above indicate the heater mounting positions. The heater mounting positions differ by the heater type. Refer to the manufacturer's catalog for replacement heater part numbers and mounting positions.
XLD Series diagram
*Refer to the manufacturer's catalog for maintenance parts.
Initial exhaust valve conductance settings graph
Note: The adjustment nut does not rotate during valve operation. However, rotation of the adjustment nut can be fixed to prevent operation errors. To fix the adjustment nut after setting it, tighten it to the torque shown under "A" Section Thread Tightening Torque" below. (Applying excessive torque can result in damaged components or abnormal noises.)
""A" Section Thread Tightening Torque
Codice componente
|
---|
XLD-40L-M9// |
Codice componente |
Prezzo unitario standard
| Quantità minima d'ordine | Sconto volumi elevati | Ghiere con flangia | Conduttanza sonica | Direzione porta pilota | Codice componente interruttore | |
---|---|---|---|---|---|---|---|---|
1,060.13 € | 1 | 22 giorni | 40 | 45L/S | Superficie flangia, posteriore | Senza interruttore automatico (con magnete incorporato) |
Loading...
Tipo | Valvole per vuoto, funzionamento a vuoto | Applicazione | Funzionamento a elemento singolo | Metodo di installazione | Diretto |
---|---|---|---|---|---|
N. di raccordi | Valvola a 2 porte | A commutazione | 2 posizioni, normalmente chiuso | Tipo di attacco tubo | Flangia |
Con flangia | KF | Con tenuta | Guarnizione a soffietto | Gamma di temperature(°C) | 5–60 |
Numero di interruttori | Senza interruttore | Materiale guarnizione | FKM 1349-80 | Perdita(Pa·m3/s) | Interno: 1.3 × 10-10, esterno: 1.3 × 10-11 |
Trattamento superficie corpo | Esterno: alluminio anodizzato rigido, interno: materiale base | Modifica posizione guarnizione | Assente | Riscaldatore sì/no | Assente |
Si trova sulla pagina di XL*, valvola ad angolo vuoto elevato, azionamento pneumatico, il codice articolo è il seguente: XLD-40L-M9//.
Ulteriori dettagli concernenti specifiche e dimensioni si trovano sotto il codice prodotto XLD-40L-M9//.
Configura
Proprietà di base
Tipo
Ghiere con flangia
Conduttanza sonica
Direzione porta pilota
Codice componente interruttore
Filtrare per tipo dati CAD
Filtrare per giorni di spedizione standard
Attributi opzionali
Codice componente |
---|
XLD-25L-M9// |
XLD-40 |
Codice componente | Prezzo unitario standard | Quantità minima d'ordine | Sconto volumi elevati | Giorni spedizione standard ? | Ghiere con flangia | Conduttanza sonica | Direzione porta pilota | Codice componente interruttore |
---|---|---|---|---|---|---|---|---|
884.79 € | 1 | 26 giorni | 25 | 14L/S | Superficie flangia, posteriore | Senza interruttore automatico (con magnete incorporato) | ||
1,283.57 € | 1 | 22 giorni | 40 | 45L/S | Lato flangia | Senza interruttore automatico (senza magnete incorporato) |