ITVX, Regolatore elettropneumatico per alta pressione (ITVX2030-31F3CL3)

ITVX, Regolatore elettropneumatico per alta pressione ITVX2030-31F3CL3

Dettagli del prodotto:

Codice articolo del costruttore: ITVX2030-31F3CL3

Marca: SMC

Prezzo: 1,781.21

Tempi di consegna: 26 giorni


Dati Tecnici:

Lato mandata, tipo di collegamento: G

Lato controllo, tipi di collegamento: G

Manometro: Con sensore di pressione

Segnale di ingresso/Segnale di comunicazione: [0–10V DC] Tensione 0–10V DC

Accessory: Staffa a L


(i)Nota

  • ■ SMC Product Line
    Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.
    Click here for a quotation or to make an order if you have a model number.

    ■ Products Planned for Online Release
    Air cylinder-related product pages will be released on this site on an ad-hoc basis.
    CQ2, MG types, etc., are already available. Click here to check.
    *Vacuum equipment, FRLs, solenoid valves, etc., will also be released on dedicated pages on this site on an ad-hoc basis.
    *The information above is correct as of December 2018.
  • See the catalog for specification details.
  • Product images may be representative images. Refer to the catalog for details.

Codice componente

Qui sono indicati i codici componente
correlati al prodotto ricercato

ITVX2030-31F3CL3

ITVX2000 Series 5.0 MPa High-Pressure Electro-Pneumatic Regulator Specifications

ITVX2000 Series application example: laser beam machine

ITVX2000 Series application example: laser beam machine

ITVX2000 Series JIS symbol

ITVX2000 Series JIS symbol

Input/output correspondence chart

Input/output correspondence chart

Model ITVX2000
Minimum supply pressure Whichever is higher: 0.5 MPa or the set pressure + 0.2 MPa
Maximum supply pressure 5 MPa*2
Set pressure range *1 0.01 to 3.0 MPa
Power Supply Voltage 24 V DC ±10%
Current Consumption 0.12 A or less
Input Signal Current type*4 4 to 20 mA DC, 0 to 20 mA DC (sink type)
Voltage type 0 to 5 V DC, 0 to 10 V DC
Input
Impedance
Current type 500 Ω or less
Voltage type 6 to 6.5kΩ (at normal temperature)
Output signal*5 (monitor output) Analog Output 1 to 5 V DC (output impedance approx. 1 kΩ)
Output accuracy ±6% or less (full span)
4 to 20 mA (sink type) load impedance 250 Ω or less
Output accuracy ±6% or less (full span)
Switch output NPN open collector output max. 30 V, 80 mA
Hysteresis ±3% (full span), self-diagnosis ±5% or less (full span)
PNP open collector output: max. 80 mA
Hysteresis ±3% (full span), self-diagnosis ±5% or less (full span)
Linearity ±1% or less (full span)
Hysteresis 1% or less (full span)
Repeatability ±1% or less (full span)
Sensitivity ±1% or less (full span)
Temperature characteristics ±0.12% or less (full span) / °C
Output pressure display Accuracy ±2% or less (full span) ±1 digit
Minimum unit*6 MPa: 0.01, kgf/cm2: 0.1, bar: 0.1, psi: 1
Fluid Air, N2, O2, Ar
Ambient and fluid temperature 0 to 50°C (no condensation)
Weight Approx. 570 g (without options)

*1: The above characteristics assume the piping conditions shown in the figure below.

Piping schematic

Piping schematic

*2: When oxygen is used as a fluid, the maximum supply pressure must be less than 1 MPa.
*3: Refer to the figure for the relationship between the set pressure and input signal.
*4: 2-wire type 4 to 20 mA DC not supported. Power supply voltage 24 V DC is required.
*5: Select one of either analog output or switch output. If switch output is selected, select either NPN output or PNP output. When measuring analog output from 1 to 5 V DC with a load impedance of less than 100 kΩ, an analog output accuracy of within ±6% (full span) may not be available.
*6: Adjustment of numerical values such as the zero/span adjustment is set based on the minimum unit for the output pressure display. The unit cannot be changed.
*7: This product is only for blowing gas. This product does not have sufficient pressure control for applications other than blowing (driving, sealing, etc.).
*8: This product does not conform to the High Pressure Gas Safety Law (Japan).

Working Principle

Working principle diagram

Working principle diagram

When the input signal rises, air supply solenoid valve (1) turns ON, and exhaust solenoid valve (2) turns OFF. Therefore, supply pressure regulated by built-in regulator (3) passes through air supply solenoid valve (1) and is applied to pilot chamber (4). The pressure in pilot chamber (4) increases and operates on the upper surface of diaphragm (5).
As a result, air supply valve (6) linked to diaphragm (5) opens, and a portion of the supply pressure becomes output pressure.
This output pressure feeds back to control circuit (8) via pressure sensor (7). Here, a correction operation functions until the output pressure is proportional to the input signal, making it possible to always obtain output pressure proportional to the input signal.

Dimensions

 

(Unit: mm)

 

ITVX2000 Series dimensional drawing

ITVX2000 Series dimensional drawing

 

(Unit: mm)

 

Straight type / right-angle type dimensional drawing

Straight type / right-angle type dimensional drawing

 

(Unit: mm)

 

G thread dimensional drawing

G thread dimensional drawing

 

(Unit: mm)

 

With flat bracket (option) dimensional drawing

With flat bracket (option) dimensional drawing

 

(Unit: mm)

 

With L-bracket (option) dimensional drawing

With L-bracket (option) dimensional drawing

Precautions

  • *Screw piping together with the recommended proper torque while holding the side with the female threads. Looseness or faulty sealing will occur if tightening torque is insufficient, while thread damage or other problems will result if the torque is excessive. Furthermore, if the side with the female threads is not held while tightening, excessive force will be applied directly to piping brackets etc., causing damage or other problems.
  • Port size M5: recommended proper torque 1.5 to 2 N·m
  • Port size 1/4: recommended proper torque 8 to 12 N·m
  • Port size 3/8: recommended proper torque 15 to 20 N·m
  • *Do not allow twisting or bending moment to be applied other than the weight of the equipment. Provide separate support for external piping, as damage may otherwise occur.
  • *Since excessive moment loads and the propagation of vibrations, etc. can easily result from inflexible piping made of materials such as steel, avoid these problems by using flexible tubing for intermediate connections.
  • *Be sure to read the safety precautions as well as the common precautions in the manufacturer's catalog before use.
  • *The images for this product are representative images. *The product shown may differ from the actual product.
  • *See the manufacturer's catalog for information other than the above.
Codice componente
ITVX2030-31F3CL3
Codice componenteRelativo a
Prezzo unitario standard
Quantità minima d'ordineSconto volumi elevati
Giorni
spedizione standard
?
Lato mandata, tipo di collegamento Lato controllo, tipi di collegamento Manometro Segnale di ingresso/Segnale di comunicazione Accessory Set Pressure Pressure Unit Monitor Output Cable Connector Type
-

1,781.21 €

1 26 giorni GGCon sensore di pressione[0–10V DC] Tensione 0–10V DCStaffa a L0.01–3.0MPabarUscita analogica 1–5V DCAd angolo retto 3m

Loading...

  1. 1

Informazioni di base

Regolatore, valvola di sovrapressione Regolatore Regolatore Elettropneumatico Liquido applicabile Aria / Azoto / Gas
Profilo Standard Ambiente d'esercizio Standard Meccanismo di scarico Disponibile
Funzione corrente contraria NA Lato mandata, diam. collegamento 3/8 Direzione flusso Da sinistra a destra
Lato di controllo, diametro collegamento 3/8 Details of Applicable Fluids Aria, N2, O2, Ar

Si trova sulla pagina di ITVX, Regolatore elettropneumatico per alta pressione, il codice articolo è il seguente: ITVX2030-31F3CL3.
Ulteriori dettagli concernenti specifiche e dimensioni si trovano sotto il codice prodotto ITVX2030-31F3CL3.

Tipologia prodotto

Codice componente
ITVX2030-01F3CL3
ITVX2030-01F3N
ITVX2030-01N3BL3
ITVX2030-31F3CN3
ITVX2030-31F3CS3
ITVX2030-31F3L3
Codice componenteRelativo a Prezzo unitario standardQuantità minima d'ordineSconto volumi elevatiGiorni
spedizione standard
?
Lato mandata, tipo di collegamento Lato controllo, tipi di collegamento Manometro Segnale di ingresso/Segnale di comunicazione Accessory Set Pressure Pressure Unit Monitor Output Cable Connector Type
-

1,780.94 €

1 26 giorni GGCon sensore di pressione[DC4-20mA] Corrente DC 4–20mA (sincr.)Staffa a L0.01–3.0MPabarUscita analogica 1–5V DCAd angolo retto 3m
-

1,742.48 €

1 4 giorni GGCon sensore di pressione[DC4-20mA] Corrente DC 4–20mA (sincr.)Senza Supporto0.01–3.0 MPaMPaUscita analogica 1–5V DCSenza connettore cavo
-

1,781.24 €

1 26 giorni [NPT] NPT[NPT] NPTCon sensore di pressione[DC4-20mA] Corrente DC 4–20mA (sincr.)Staffa profilo piatto0.01–3.0MPabarUscita analogica 1–5V DCAd angolo retto 3m
-

1,747.05 €

1 26 giorni GGCon sensore di pressione[0–10V DC] Tensione 0–10V DCStaffa a L0.01–3.0MPabarUscita analogica 1–5V DCSenza connettore cavo
-

1,781.24 €

1 26 giorni GGCon sensore di pressione[0–10V DC] Tensione 0–10V DCStaffa a L0.01–3.0MPabarUscita analogica 1–5V DCTipo dritto 3m
-

1,776.66 €

1 26 giorni GGCon sensore di pressione[0–10V DC] Tensione 0–10V DCSenza staffa0.01–3.0MPabarUscita analogica 1–5V DCAd angolo retto 3m

Supporto tecnico